Evaluation of the Enterprise Point-of-Care (EPOC) System for Blood Gas and Electrolyte Analysis

نویسندگان

  • James H. Nichols
  • Aparna Rajadhyaksha
چکیده

Objective: To evaluate the analytical performance of a new point-ofcare blood gas and electrolyte analyzer, the EPOC system. Materials and Methods: Evaluation of analytical precision and method comparison was conducted at the manufacturing facilities and at several locations in a 630-bed tertiary acute care hospital in New England, an intensive care unit, cardiac intensive care unit, an outpatient hematology/oncology clinic, and the Baystate Health system central laboratory (Springfield, Mass). The evaluation was conducted by nursing staff, medical laboratory technicians, medical technologists, and pathology residents. Results: Within-run precision (0.07%Y2.3% coefficient of variation [CV]) and total precision (0.14%Y3.8% CV) were estimated by analysis of aqueous and hematocrit control materials. A total of 143 samples leftover from laboratory analysis were compared with the predicate device, the i-STAT. One sample was excluded for potential benzalkonium interference with electrolytes, and another sample was excluded from the hematocrit correlation because of suspected incomplete mixing. The EPOC system was comparable to the i-STAT for all analytes with correlation coefficients of 0.880 to 0.990, linear regression slopes of 0.91 to 1.07, and SE of the estimates of 1.5% to 2.5% CV for electrolytes and pH, 3.9% for hematocrit, and 4.9% to 7.3% CV for blood gases. Conclusions: The EPOC system demonstrated excellent analytical precision and comparability of patient results to the i-STAT. The EPOC system has room temperature storage of test cards and wireless connectivity that provides an operational advantage over other pointof-care blood gas analyzers on the market.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of capillary blood analysis and capillary testing mode on the epoc Point of Care system

BACKGROUND Laboratory test in transport is a critical component of patient care, and capillary blood is a preferred sample type particularly in children. This study evaluated the performance of capillary blood testing on the epoc Point of Care Blood Analysis System (Alere Inc). METHODS Ten fresh venous blood samples was tested on the epoc system under the capillary mode. Correlation with GEM ...

متن کامل

An Evaluation of Four Electrolyte Models for the Prediction of Thermodynamic Properties of Aqueous Electrolyte Solutions

In this work, the performance of four electrolyte models for prediction the osmotic and activity coefficients of different aqueous salt solutions at 298 K, atmospheric pressure and in a wide range of concentrations are evaluated. In two of these models, (electrolyte Non-Random Two-Liquid e-NRTL and Mean Spherical Approximation-Non-Random Two-Liquid MSA-NRTL), association between ions of opposit...

متن کامل

Analytical and clinical performance of the epoc blood analysis system: experience at a large tertiary academic medical center.

OBJECTIVES To describe validation and performance of epoc, a blood gas analysis point-of-care system, in a live clinical setting. METHODS Data were collected for 156 epoc systems over 12 months. Preimplementation precision and correlation studies and postimplementation quality assurance data were collected, including test card, reader, and personal data assistant (PDA) failure rates. RESULT...

متن کامل

Advanced Analysis of Dew Point Control Unit of Hybrid Refrigeration Systems in Gas Refineries

In this paper, an advanced analysis of a novel hybrid compression-absorption refrigeration system (HCARS) for natural gas dew point control unit in a gas refinery is presented. This unit separates the heavy hydrocarbon molecules in the natural gas, which is traditionally carried out by natural gas cooling in a compression refrigeration cycle (CRS). The power input required for the refrigeration...

متن کامل

A Double Pipe Heat Exchanger Design and Optimization for Cooling an Alkaline Fuel Cell System

In the presented research, heat transfer of a mobile electrolyte alkaline fuel cell (AFC) (which the electrolyte has cooling role of system) has been considered. Proper control volumes of system with specific qualification have been chosen. Consequently, heat and mass transfer in control volumes have been assessed. Considerations on them and contributed models lead to approve a double tube heat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008