Detection of horizontal root fracture using four different protocols of cone-beam computed tomography.
نویسندگان
چکیده
The purpose of this study was to analyze four different cone-beam computed tomography (CBCT) protocols to identify horizontal root fractures (HRF) in endodontically treated teeth, with or without the presence of a metallic post. Thirty extracted single-rooted human premolars were treated endodontically. Afterwards, an observer induced a horizontal fracture in 15 teeth. Each tooth was inserted in an empty mandibular socket and submitted to a computed tomography scan taken with and without the metallic post. The acquisition followed four different protocols, with different fields of view (FOV) and voxel sizes, as follows: FOV 6 X 16 cm/0.2 mm voxel; FOV 6 X 16 cm/0.25 mm voxel; FOV 8 X 8 cm/0.2 mm voxel; FOV 8 X 8 cm/0.25 mm voxel. Two observers checked all the acquisitions within a two-week interval, and the values of sensitivity, specificity, accuracy and kappa were calculated. The sensitivity, specificity and accuracy values were better for the 8 X 8 cm/0.2 mm and 16 X 6 cm/0.25 mm protocols, ranging from 0.60 to 0.86 and 0.53 to 0.80, respectively. The intra- and interobserver concordance ranged from 0.65 to 0.72. The protocols where FOV and voxel were proportional showed better results. The 8 x 8 cm/0.2 mm protocol had the least interference from the metallic artifact. All four protocols showed a decline in values in the presence of the metallic artifact.
منابع مشابه
Cone-beam computed tomography performance and endodontic filling material influence in the diagnosis of horizontal root fracture
Introduction: The aim of this study was to investigate the accuracy of Cone-beam computed tomography(CBCT) in detecting the horizontal root fractures (HRFs) in teeth with and without gutta-percha. Materials & Methods: This in vitro study was performed on 100 mandibular and maxillary single-rooted teeth. In 55 samples, the canals were prepared. Then, the horizontal fracture was induced randomly...
متن کاملDiagnostic Accuracy of Different Resolutions of Cone Beam Computed Tomography Imaging System for Detection of Vertical Root Fractures In Presence of Casting Posts
Objective: The diagnosis of vertical root fracture (VRF) in endodontically treated teeth is a clinical challenge due to lack of specific clinical and radiographic signs. Although radiographic evaluation such as CBCT is helpful, intracanal posts can produce artifacts and may impair the quality of CBCT scans. This study aimed to compare the diagnostic accuracy of different resolutions of CBCT i...
متن کاملComparison of cone beam computed tomography and digital radiography in detection of pulpal exposure in external cervical root resorption
Background and Aims: Pulpal exposures originated from the external cervical root resorptions have major effects on the treatment and prognosis. Therefore, the aim of this study was performed to compare the two different imaging systems-digital radiography with PSP (Photostimulable Phosphor) sensor in three horizontal different views and CBCT (cone beam computed tomography) images to assess the ...
متن کاملComparison of Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography for Detection of Vertical Root Fractures with and without Gutta Percha
Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics which most of the times occurs in endodontically treated teeth with root canal fillings such as gutta percha. Despite Cone Beam Computed Tomography (CBCT) has significantly enhanced image quality compared to digital radiography (DR) which aid the diagnosis, artifacts has remained as a problem in VRF detection . ...
متن کاملDifferences in Healing of a Horizontal Root Fracture as Seen on Conventional Periapical Radiography and Cone-Beam Computed Tomography
Different locations and healing patterns of horizontal root fractures bear different prognoses. Conventional periapical radiographs have been routinely used for the evaluation of the locations and healing of horizontal root fractures, with the limitation of presenting two-dimensional images. The three-dimensional imaging technology, cone-beam computed tomography (CBCT), has recently gained inte...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Brazilian oral research
دوره 29 شماره
صفحات -
تاریخ انتشار 2015