Virtual Hip Replacement Simulator for 3D Printed Implants

نویسندگان

  • Neil Vaughan
  • Venketesh N. Dubey
چکیده

This research presents a virtual reality simulator for total hip replacement surgery. The simulator supports a library of 3D hip stem models for different sizes and manufacturers. The 3D hip stems can be adjusted in size and shape by parametric software and sent for 3D printing. Biocompatible materials such as titanium enable the 3D printed stems to be directly implanted on patients. Currently surgical simulation for orthopaedic procedures is not as advanced as other surgical disciplines. As a result there are only limited training simulators available for orthopaedic surgery such as total hip replacement, hip resurfacing or knee replacement. This is demanding since 66,000 hip replacements are performed annually in the UK. One area which is neglected in VR orthopaedic simulation is the digital library generation of implants. Currently orthopaedic surgeons have limited choice in terms of an exact identification of implant specific to patient requirements. We conducted a literature review of orthopaedic training simulators which found no simulators catering for this [9]. Orthopaedic surgeons generally have a positive opinion for the use of virtual reality (VR) training systems. A survey amongst all orthopaedic surgeons in New Zealand found that 77% of qualified surgeons believe simulation is effective for practicing and learning surgical procedures [1]. A separate review from the American Academy of Orthopaedic Surgeons (AAOS) showed that over 80% agreed that surgical skills simulations should become a required part of orthopaedic training, based on views from 185 program directors and 4549 residents. There was a strong agreement that simulation technology should be a required component of orthopaedic resident training [2]. The hip replacement procedure has been considered as the most successful and influential orthopaedic surgery of the twentieth century. Currently over 66,000 total hip replacements (THR) are performed each year in England and Wales by the National Health Service (NHS) and around 75,000 hip fractures are treated each year in the UK. Knee arthroscopy has increased 49% from 1996-2006 and now over 1 million are performed each year [3]. Each year there are an increasing number of orthopaedic procedures due to the aging population. Currently 247,000 hip fractures occur yearly in the United States, with the majority occurring in the population over 45 years old [4]. The incidence of hip fracture is also on the rise, partly due to the aging population, with over half a million hip fractures annually expected by 2040. The cost of these fractures is also expected to rise from $7 billion per year [4], to nearly $16 billion per year by 2040 [5]. Each hip fracture is estimated at costing between $39,555 and $40,600 in the first year after surgery [6]. Hip fractures have the highest cost of any orthopaedic procedure after surgery, and also incur $11,241 each year following surgery in extra health costs. Due to increased life expectancy, worldwide by 2050, it is projected that 6.26 million hip fractures will occur annually [7]. A paradigm shift is underway toward use of surgical training simulations [8]. The conventional master-apprentice learning model for surgical training of ‘see one, do one, teach one’ has recently been seen as inefficient. Due to orthopaedics being heavily dependent on technical skill, orthopaedic VR simulation holds potential to have great impact for improving surgical skill. The transition to VR simulation is relatively new compared to cadaver training which has been the gold standard for several centuries.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fully porous 3D printed titanium femoral stem to reduce stress-shielding following total hip arthroplasty.

Current hip replacement femoral implants are made of fully solid materials which all have stiffness considerably higher than that of bone. This mechanical mismatch can cause significant bone resorption secondary to stress shielding, which can lead to serious complications such as peri-prosthetic fracture during or after revision surgery. In this work, a high strength fully porous material with ...

متن کامل

A 3D-Printed Sensor for Monitoring Biosignals in Small Animals

Although additive manufacturing technologies, also known as 3D printing, were first introduced in the 1980s, they have recently gained remarkable popularity owing to decreased costs. 3D printing has already emerged as a viable technology in many industries; in particular, it is a good replacement for microfabrication technology. Microfabrication technology usually requires expensive clean room ...

متن کامل

A review of virtual reality based training simulators for orthopaedic surgery.

This review presents current virtual reality based training simulators for hip, knee and other orthopaedic surgery, including elective and trauma surgical procedures. There have not been any reviews focussing on hip and knee orthopaedic simulators. A comparison of existing simulator features is provided to identify what is missing and what is required to improve upon current simulators. In tota...

متن کامل

Wear Testing of Total Hip Joints According to Iso and Development of a New Hip Joint Simulator According to Iso

INTRODUCTION The development of new, highly sophisticated materials for the articulating surfaces of total hip endoprostheses has led to an increasing demand for testing and verification. This includes tests and research regarding bio-compatibility, static load bearing capacity of the prostheses as well as tribological investigations. Since it has been found that wear debris play a dominant rol...

متن کامل

A 3D Simulation System for Hip Joint Replacement Planning

We present a tool for hip joint replacement planning that allows the surgeon to rank the long-term stability of an implant, and we show the application of this tool in a clinical routine setting. The tool allows the surgeon to predict the load transmission of an implant to the patient-specific bone. It is used to select of a set of available implants the one that most closely replicates the phy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016