X-ray micromodulated luminescence tomography in dual-cone geometry.
نویسندگان
چکیده
We propose a scanning method utilizing dual-cone beams of x-rays to induce luminescence from nanophosphors and reconstruct the three-dimensional distribution of these particles in a biological sample or a small animal. For this purpose, x-rays are focused through a polycapillary lens onto a spot of a few micrometers in size. Such x-ray scanning can be point-wise performed to acquire photon emission data on an object surface. The x-ray-induced luminescence data allow for reliable image reconstruction with high spatial resolution and large imaging depth. We describe several numerical simulation studies to demonstrate the feasibility and merits of the proposed approach.
منابع مشابه
Cone Beam X-Ray Luminescence Tomography Imaging Based on KA-FEM Method for Small Animals
Cone beam X-ray luminescence tomography can realize fast X-ray luminescence tomography imaging with relatively low scanning time compared with narrow beam X-ray luminescence tomography. However, cone beam X-ray luminescence tomography suffers from an ill-posed reconstruction problem. First, the feasibility of experiments with different penetration and multispectra in small animal has been teste...
متن کاملA wavelet-based single-view reconstruction approach for cone beam x-ray luminescence tomography imaging.
Single-view x-ray luminescence computed tomography (XLCT) imaging has short data collection time that allows non-invasively and fast resolving the three-dimensional (3-D) distribution of x-ray-excitable nanophosphors within small animal in vivo. However, the single-view reconstruction suffers from a severe ill-posed problem because only one angle data is used in the reconstruction. To alleviate...
متن کاملMeasurement of eye lens dose for Varian On-Board Imaging with different cone-beam computed tomography acquisition techniques
The objective of this work was to measure patient eye lens dose for different cone-beam computed tomography (CBCT) acquisition protocols of Varian's On-Board Imaging (OBI) system using optically stimulated luminescence dosimeter (OSLD) and to study the variation in eye lens dose with patient geometry and distance of isocenter to the eye lens. During the experimental measurements, OSLD was place...
متن کاملMeasurement of skin dose from cone-beam computed tomography imaging
OBJECTIVE To measure surface skin dose from various cone-beam computed tomography (CBCT) scanners using point-dosimeters. MATERIALS & METHODS A head anthropomorphic phantom was used with nanoDOT optically stimulated luminescence (OSL) dosimeters (Landauer Corp., Glenwood, IL) attached to various anatomic landmarks. The phantom was scanned using multiple exposure protocols for craniofacial eva...
متن کاملThe Use of Radiographs, Dual-energy X-ray Absorptiometry, Quantitative Computed Tomography and Micro-computed Tomography to Determine Local Cancellous Bone Quality in the Canine Proximal Femur
.......................................................................................................ii Acknowledgements ......................................................................................iv Vita ...............................................................................................................vi List of Tables ......................................................
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomedical optics
دوره 19 7 شماره
صفحات -
تاریخ انتشار 2014