Volume assessment accuracy in computed tomography: a phantom study
نویسندگان
چکیده
There is a broad push in the cancer imaging community to eventually replace linear tumor measurements with three-dimensional evaluation of tumor volume. To evaluate the potential accuracy of volume measurement in tumors by CT, a gelatin phantom consisting of 55 polymethylmethacrylate (PMMA) spheres spanning diameters from 1.6 mm to 25.4 mm was fabricated and scanned using thin slice (0.625 mm) CT (GE LightSpeed 16). Nine different reconstruction combinations of field of view dimension (FOV = 20, 30, 40 cm) and CT kernel (standard, lung, bone) were analyzed. Contiguous thin-slice images were averaged to produce CT images with greater thicknesses (1.25, 2.50, 5.0 mm). Simple grayscale thresholding techniques were used to segment the PMMA spheres from the gelatin background, where a total of 1800 spherical volumes were evaluated across the permutations studied. The geometric simplicity of the phantom established upper limits on measurement accuracy. In general, smaller slice thickness and larger sphere diameters produced more accurate volume assessment than larger slice thickness and smaller sphere diameter. The measured volumes were smaller than the actual volumes by a common factor depending on slice thickness; overall, 0.625 mm slices produced on average 18%, 1.25 mm slices produced 22%, 2.5 mm CT slices produced 29%, and 5.0 mm slices produced 39% underestimates of volume (mm3). Field of view did not have a significant effect on volume accuracy. Reconstruction algorithm significantly affected volume accuracy (p < 0.0001), with the lung kernel having the smallest error, followed by the bone and standard kernels. The results of this investigation provide guidance for CT protocol development and may guide the development of more advanced techniques to promote quantitatively accurate CT volumetric analysis of tumors.
منابع مشابه
Dose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran
Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...
متن کاملDesign and Construction of an Affordable Phantom for Electron Density Measurement and Linearity Tests of Computed Tomography Systems
Introduction: The performance of computed tomography is routinely checked using phantoms, which are known as important diagnostic imaging tools. Depending upon the aim of the study, different phantoms are designed, while trying to satisfy certain levels of diversities in their application. Material and Methods: The present study describes the...
متن کاملAssessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method
Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...
متن کاملEffect of Phantom Size and Tube Voltage on the Size-Conversion Factor for Patient Dose Estimation in Computed Tomography Examinations
Introduction: This study aimed to establish the conversion factors to normalize the output dose of volumetric computed tomography dose index (CTDIvol) to the patient dose (i.e. size-specific dose estimate (SSDE)) for various phantom diameters and tube voltages. Material and Methods: In-house cylindrical acrylic phantoms with physical diameter...
متن کاملOptimization of Radiation Dose in Cranial Computed Tomography among Adults: Assessment of Radiation Dose against Image Quality
Introduction: The rapid use of computed tomography (CT) scan is of great concern, due to increase in patients’ dose. Optimization of CT protocol is a vital issue in dose reduction. This study aimed to optimize radiation dose in cranial CT and assess modifications in image quality under radiation dose reduction. Material and Methods: A poly(me...
متن کاملBackground-Based Delineation of Internal Tumor Volumes on Static Positron Emission Tomography in a Phantom Study
Objective(s): Considering the fact that the standardized uptake value (SUV) of a normal lung tissue is expressed as x±SD, x+3×SD could be considered as the threshold value to outline the internal tumor volume (ITV) of a lung neoplasm. Methods: Three hollow models were filled with 55.0 kBq/mL fluorine18- fluorodeoxyglucose (18F-FDG) to represent tumors. The models were fixed to a barrel filled w...
متن کامل