Attenuation compensation in single-photon emission tomography: a comparative evaluation.

نویسندگان

  • M H Lewis
  • J T Willerson
  • S E Lewis
  • F J Bonte
  • R W Parkey
  • E M Stokely
چکیده

Attenuation of photons in single-photon emission tomography (SPECT) makes three-dimensional reconstruction of unknown radioactivity distributions a mathematically intractable problem. Approaches to approximate SPECT reconstruction range from ignoring the effect of photon attenuation to incorporating assumed attenuation coefficients into an iterative reconstruction procedure. We have developed a computer-based simulation method to assess the relative effectiveness of attenuation compensation procedures. The method was used to study four procedures for myocardial SPECT using an infarct-avid radiopharmaceutical, Tc-99m stannous pyrophosphate. Reconstructions were evaluated by two criteria: overall (sum-of-squares) accuracy, and accuracy of lesion sizing. For moderate- to high-contrast studies there were no significant differences among the reconstructions by either evaluation criterion; for low contrast ratios the iterative method produced lower sum-of-squares criterion; for low contrast ratios the iterative method produced lower sum-of-squares error. We conclude that the additional expense of the iterative method is not justified under the conditions of this study. The approach used here is a convenient tool for evaluating specific SPECT reconstruction alternatives.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Review of transmission scanning configurations in cardiac SPECT

The diagnostic accuracy of single photon emission computed tomography (SPECT) is profoundly influenced by attenuation phenomenon. Soft tissue attenuation degrades cardiac SPECT image quality, thereby decreasing the possibility of the detection of the lesions. A variety of correction techniques based on different assumptions have been used to reduce the impact of attenuation. Several types of sy...

متن کامل

Monte Carlo Study of the Effect of Backscatter Materail Thickness on 99mTc Source Response in Single Photon Emission Computed Tomography

Introduction SPECT projections are contaminated by scatter radiation, resulting in reduced image contrast and quantitative errors. Backscatter constitutes a major part of the scatter contamination in lower energy windows. The current study is an evaluation of the effect of backscatter material on FWHM and image quality investigated by Monte Carlo simulation. Materials and Methods SIMIND program...

متن کامل

GPU-based acceleration of the MLEM algorithm for SPECT parallel imaging with attenuation correction and compensation for detector response

Parallel projection based Single Photon Emission Computed Tomography (SPECT) is one of the most widely used nuclear imaging technique even nowadays. Serious artefacts are produced in the reconstructed images due to the non-homogeneous attenuation medium and the distance dependent spatial resolution (DDSR) of the parallel imaging. Effective non-uniform attenuation correction and DDSR reduction p...

متن کامل

Nonlinear Dual Reconstruction of SPECT Activity and Attenuation Images

In single photon emission computed tomography (SPECT), accurate attenuation maps are needed to perform essential attenuation compensation for high quality radioactivity estimation. Formulating the SPECT activity and attenuation reconstruction tasks as coupled signal estimation and system parameter identification problems, where the activity distribution and the attenuation parameter are treated...

متن کامل

Simultaneous compensation for attenuation, scatter and detector response for SPECT reconstruction in three dimensions.

A three-dimensional reconstruction method for simultaneous compensation of attenuation, scatter and distance-dependent detector response for single photon emission computed tomography is described and tested by experimental studies. The method determines the attenuation factors recursively along each projection ray starting at the intersected source voxel closest to the detector. The method sub...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 23 12  شماره 

صفحات  -

تاریخ انتشار 1982