Computed spectroscopy using segmented apertures
نویسندگان
چکیده
A novel technique for imaging spectroscopy is introduced. The technique makes use of an optical imaging system with a segmented aperture and intensity detector array on the imaging plane. The point spread function (PSF) of such a system can be adjusted by modifying the path lengths from the subapertures to the image plane, and the shape of the resulting point spread function will vary as a function of wavenumber. An image reconstruction approach is taken to convert multiple recorded pan-chromatic images with different wavenumber-varying point spread functions into a hyperspectral data set. Thus, the technique described here is a new form of computed imaging.
منابع مشابه
Introduction to passive electron intensity modulation
This work introduces a new technology for electron intensity modulation, which uses small area island blocks within the collimating aperture and small area island apertures in the collimating insert. Due to multiple Coulomb scattering, electrons contribute dose under island blocks and lateral to island apertures. By selecting appropriate lateral positions and diameters of a set of island blocks...
متن کاملIac-08-c1.8.5 Optical Beam Control for Imaging Spacecraft with Large Apertures
This paper discusses optical beam control using adaptive optics for imaging spacecraft with large aperture telescopes. The segmented mirror alignment and active mirror surface control are achieved by novel wavefront sensing and control techniques. The experimental testbed and test results are also presented to demonstrate the adaptive optics techniques for large-aperture segmented mirrors.
متن کاملA Modified Hybrid MoM-Modal Method for Shielding Effectiveness Evaluation of Rectangular Enclosures with Multiple Apertures
A new hybrid modal-moment method is proposed to calculate fields penetrated through small apertures on rectangular metallic enclosures. First, the method of moments is used to numerically solve the governing electric field integral equation for the equivalent two-dimensional surface-current distributions on the surface of metallic enclosure including any number of rectangular apertures of arbit...
متن کاملDevelopment of a Liver Phantom Based on Computed Tomography Images for Dosimetric Purpose
Introduction: The present study was conducted with the aim of designing a liver phantom for dosimetry. To benchmark the results obtained by the developed liver phantom, another method was applied for the dosimetry of a real liver tissue using imaging. Materials and Methods: For the purpose of the study, a real liver tissue was converted into a phantom based on thegram-molecular weight of the co...
متن کاملAn array of planar apertures for near-field fluorescence correlation spectroscopy.
We have developed a method of performing near-field fluorescence correlation spectroscopy via an array of planarized circular apertures of 50 nm diameter. This technique provides 1 μs and 60 nm resolution on proximal samples, including live cells, without incorporating a scanning probe or pulsed lasers or requiring penetration of the sample into the aperture. Millions of apertures are created i...
متن کامل