Noninvasive estimation of FDG input function for quantification of cerebral metabolic rate of glucose: optimization and multicenter evaluation.

نویسندگان

  • T Shiozaki
  • N Sadato
  • M Senda
  • K Ishii
  • T Tsuchida
  • Y Yonekura
  • H Fukuda
  • J Konishi
چکیده

UNLABELLED The aims of this study were to determine whether body weight or body surface area (BSA) should be used for noninvasive measurement of the cerebral metabolic rate of glucose (CMRGlc) by FDG PET with a standardized input function (SIF) and an autoradiographic method and to validate the procedure in a large population from different PET centers. METHODS Plasma input functions measured by intermittent arterial blood sampling after intravenous injection of FDG, in 101 patients from 1 institution who were fasting for at least 4 h, were used to generate the SIF. The SIF was generated by averaging over 101 patients the input function normalized with the net injected dose and initial distribution volume (DV) of FDG estimated by the formula c x Ha x Wb, where H is body height and W is body weight. To evaluate the estimation of DV by BSA or body weight, the coefficient of variation (CV) of the ratio of Ha x Wb to the measured DV was calculated by changing a and b independently. Estimation of the CMRGlc with SIF based on the formula for DV was validated with an additional 192 subjects from 3 institutions who underwent FDG PET while fasting. The result of simulation was compared with the results of 4 previously published formulas for BSA and body weight. RESULTS The optimal set of parameters, in which a was 0.80 and b was 0.35, minimized the CV. The averaged percentage error of the CMRGlc based on the optimal set of parameters for DV estimation and SIF was 8.9% for gray matter and 10.6% for white matter. Four BSA formulas brought about a similar error, which was significantly smaller than that based on body weight (P < 0.001, ANOVA). CONCLUSION Noninvasive estimation of CMRGlc is made possible by careful measurement of the net injected dose and BSA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Noninvasive quantification of cerebral metabolic rate for glucose in rats using 18F-FDG PET and standard input function

Measurement of arterial input function (AIF) for quantitative positron emission tomography (PET) studies is technically challenging. The present study aimed to develop a method based on a standard arterial input function (SIF) to estimate input function without blood sampling. We performed (18)F-fluolodeoxyglucose studies accompanied by continuous blood sampling for measurement of AIF in 11 rat...

متن کامل

Noninvasive quantification of the cerebral metabolic rate for glucose using positron emission tomography, 18F-fluoro-2-deoxyglucose, the Patlak method, and an image-derived input function.

The authors developed and tested a method for the noninvasive quantification of the cerebral metabolic rate for glucose (CMRglc) using positron emission tomography (PET), 18F-fluoro-2-deoxyglucose, the Patlak method, and an image-derived input function. Dynamic PET data acquired 12 to 48 seconds after rapid tracer injection were summed to identify carotid artery regions of interest (ROIs). The ...

متن کامل

Characterization of the image-derived carotid artery input function using independent component analysis for the quantitation of [18F] fluorodeoxyglucose positron emission tomography images Image-derived input function by ICA for FDG-PET

We previously developed a noninvasive technique for the quantification of fluorodeoxyglucose (FDG) positron emission tomography (PET) images using an imagederived input function obtained from a manually drawn carotid artery region. Here, we investigate the use of independent component analysis (ICA) for more objective identification of the carotid artery and surrounding tissue regions. Using FD...

متن کامل

Characterization of the image-derived carotid artery input function using independent component analysis

We previously developed a noninvasive technique for the quantification of fluorodeoxyglucose (FDG) positron emission tomography (PET) images using an image-derived input function obtained from a manually drawn carotid artery region. Here, we investigate the use of independent component analysis (ICA) for more objective identification of the carotid artery and surrounding tissue regions. Using F...

متن کامل

Estimation of an image derived input function with MR-defined carotid arteries in FDG-PET human studies using a novel partial volume correction method.

Kinetic analysis of 18F-fluorodeoxyglucose positron emission tomography data requires an accurate knowledge the arterial input function. The gold standard method to measure the arterial input function requires collection of arterial blood samples and is an invasive method. Measuring an image derived input function is a non-invasive alternative but is challenging due to partial volume effects ca...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 41 10  شماره 

صفحات  -

تاریخ انتشار 2000