Pulsed Doppler echocardiography for diagnosis of ventricular septal defects.

نویسندگان

  • A Magherini
  • G Azzolina
  • V Wiechmann
  • F Fantini
چکیده

In order to assess the performance of pulsed Doppler echocardiography and to examine the factors affecting its reliability for the diagnosis of ventricular septal defects, 51 patients, in whom angiographic studies had recently been performed, were investigated before and after operation by this technique. The diagnosis was correct in all cases with left-to-right shunt, when the defect was located either in the upper muscular or in the infracristal portion of the septum, even when pulmonary hypertension or additional cardiac malformations were present. Pulsed Doppler echocardiography did not differentiate between supracristal ventricular septal defects and obstruction of the right ventricular outflow. Apical muscular defects were never observed in our cases. Defects of the inlet portion were not localised by the method. In cases with bidirectional shunt, pulsed Doppler echocardiography failed to provide any diagnostic clue. When a right-to-left shunt was present, only in one case with membranous pseudoaneurysm could pulsed Doppler echocardiography provide an exact description of the haemodynamics before and after operation. In 12 of 22 patients with tetralogy of Fallot, pulsed Doppler echocardiography showed flow tracings possibly related to the septal defect. The site of defect and the extent and direction of intracardiac shunting seem to be the main factors affecting its diagnostic performance in ventricular septal defects.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pulsed Doppler Echocardiography in the Diagnosis of Ventricular Septal Defect and Patent Ductus Arteriosus

some limitations and it is unable to detect small abnormalities beyond the imaging resolution of the apparatus. Ventricular septal defects (VSDs) can only be detected if they are sufficiently large or are associated with certain anatomical malformation (Magherini et al., 1983). Accurate demonstration of a patent ductus arteriosus (PDA) is limited due to echo dropout which makes visualisation of...

متن کامل

Diagnosis of ventricular septal defect by pulsed Doppler echocardiography. Sensitivity, specificity and limitations.

The M-mode echocardiographic findings of ventricular septal defect (VSD) are nonspecific. A specific pulsed Doppler echocardiographic (PDE) diagnosis of VSD can be made by following the turbulent VSD jet through the septum. To assess the sensitivity, specificity and limitations of PDE diagnosis of VSD, 105 children undergoing cardiac catheterization were examined by PDE. These children had a va...

متن کامل

Normal left ventricular systolic time intervals assessed by pulsed wave Doppler echocardiography in the Turkmen horse of Iran

The Turkmen horse is one of the oldest and purest breeds in the world. There is no information with regards to the normal echocardiographic parameters of this horse regarding to cardiac diseases. Pulsed-wave (PW) Doppler echocardiography was performed on 42 clinically normal 3- to 15-year-old racing Turkmen horses. There were 26 stallions and 16 mares. The left ventricular isovolumetric contrac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British heart journal

دوره 43 2  شماره 

صفحات  -

تاریخ انتشار 1980