Eye Movement Control in the Argus II Retinal-Prosthesis Enables Reduced Head Movement and Better Localization Precision.
نویسندگان
چکیده
Purpose Visual scanning by sighted individuals is done using eye and head movements. In contrast, scanning using the Argus II is solely done by head movement, since eye movements can introduce localization errors. Here, we tested if a scanning mode utilizing eye movements increases visual stability and reduces head movements in Argus II users. Methods Eye positions were measured in real-time and were used to shift the region of interest (ROI) that is sent to the implant within the wide field of view (FOV) of the scene camera. Participants were able to use combined eye-head scanning: shifting the camera by moving their head and shifting the ROI within the FOV by eye movement. Eight blind individuals implanted with the Argus II retinal prosthesis participated in the study. A white target appeared on a touchscreen monitor and the participants were instructed to report the location of the target by touching the monitor. We compared the spread of the responses, the time to complete the task, and the amount of head movements between combined eye-head and head-only scanning. Results All participants benefited from the combined eye-head scanning mode. Better precision (i.e., narrower spread of the perceived location) was observed in six out of eight participants. Seven of eight participants were able to adopt a scanning strategy that enabled them to perform the task with significantly less head movement. Conclusions Integrating an eye tracker into the Argus II is feasible, reduces head movements in a seated localization task, and improves pointing precision.
منابع مشابه
Visual and Non-Visual Navigation in Blind Patients with a Retinal Prosthesis
Human adults with normal vision can combine visual landmark and non-visual self-motion cues to improve their navigational precision. Here we asked whether blind individuals treated with a retinal prosthesis could also benefit from using the resultant new visual signal together with non-visual information when navigating. Four patients (blind for 15-52 years) implanted with the Argus II retinal ...
متن کاملUse of the Argus II retinal prosthesis to improve visual guidance of fine hand movements.
PURPOSE We studied the capabilities of the Argus II retinal prosthesis for guiding fine hand movement, and demonstrated and quantified guidance improvement when using the device over when not using the device for progressively less predictable trajectories. METHODS A total of 21 patients with retinitis pigmentosa (RP), remaining vision no more than bare light perception, and an implanted Argu...
متن کاملRetinotopic to Spatiotopic Mapping in Blind Patients Implanted With the Argus II Retinal Prosthesis.
Purpose To quantify the precision of mapping from retinotopic (retina-centered) to spatiotopic (world-centered) coordinates in blind humans implanted with a retinal prosthesis device. Additionally, to demonstrate that an eye tracker can be calibrated on sightless patients based on the percept from a visual implant. Methods We directly activated epiretinal electrodes to create retinotopic stim...
متن کاملThe Detection of Motion by Blind Subjects With the Epiretinal 60-Electrode (Argus II) Retinal Prosthesis.
OBJECTIVE To investigate the ability of 28 blind subjects implanted with a 60-electrode Argus II (Second Sight Medical Products Inc) retinal prosthesis system to detect the direction of a moving object. METHODS Blind subjects (bare light perception or worse in both eyes) with retinitis pigmentosa were implanted with the Argus II prosthesis as part of a phase 1/2 feasibility study at multiple ...
متن کاملVisual BOLD Response in Late Blind Subjects with Argus II Retinal Prosthesis
Retinal prosthesis technologies require that the visual system downstream of the retinal circuitry be capable of transmitting and elaborating visual signals. We studied the capability of plastic remodeling in late blind subjects implanted with the Argus II Retinal Prosthesis with psychophysics and functional MRI (fMRI). After surgery, six out of seven retinitis pigmentosa (RP) blind subjects we...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 59 2 شماره
صفحات -
تاریخ انتشار 2018