The load-transfer mechanism and stress patterns in the acetabulum reconstructed with a threaded cup were investigated relative to the normal hip using the Finite Element Method (FEM). Several models were applied in the analysis to investigate the effects of axisymmetric 3-D versus 2-D approaches, inclusion of the femoral head, and local stress patterns around the threads in three types of implant/bone bonding modes. It was found that the threaded ring behaves as a relatively rigid implant shielding the trabecular bone and enhancing load transfer through the cortical shells. Load transfer from ring to bone is concentrated at the first and last threads where the subchondral bone layer is penetrated. Stress peaks of up to 24 MPa occur in these regions.
منابع مشابه
The Comparative Analysis of a Novel Acetabular Component Against Hemispherical Component in Case of Extensive Acetabular Bone Defects A Study Of Finite Element Analysis
The purpose of this study was to evaluate the design of a cup using finite element method and to analyze possible effects of joint loading postoperatively, and its initial mechanical stability, so as to direct its further optimization. Finite‐element (FE) models of the cup with three wings and the hemispherical cup were created to calculate the stress pattern...
متن کاملThe third generation of cementless cups consist of a metallic acetabular shell with a rough surface to improve osseous integration and therefore long- term survival
Prospectively the outcome after total hip replacement with a new threaded acetabular cup design was compared to an established press-fit cup. After 1, 2 and 5 years, the 36-item Short Form Health Survey, Western Ontario and McMaster University Osteoarthritis Index and Harris Hip Score revealed no significant differences between the two groups (each group : n = 42 patients), except for a higher ...
متن کاملCementless acetabular components.
Four hundred and fifteen patients with cementless acetabular components of either a smooth threaded (130) or porous surfaced (285) variety were compared for clinical symptoms and radiographic signs of component loosening. At a mean 4.8 year follow-up none of the patients with porous acetabular components had signs of component instability. At a mean 3.9 year follow-up 27 (21%) of the patients w...
متن کاملPrimary Migration of Fully-threaded Acetabular Prostheses
We investigated the fixation of fully-threaded cementless acetabular prostheses in 20 patients with osteoarthritis, measuring the migration of the cup using roentgen stereophotogrammetric analysis (RSA). All the cups migrated proximally, 13 moved laterally or medially, and nine moved anteriorly or posteriorly in the first two postoperative years, the average migration being 1.1 to 1.4 mm in eit...
متن کاملUnsatisfactory results with the cementless Omnifit acetabular component due to polyethylene and severe osteolysis.
A high incidence of acetabular osteolysis (43%), associated with osteolytic lesions in the proximal femur (22.6%) and leading to a high revision rate, was experienced with the Omnifit total hip prosthesis. We reviewed the clinical and radiological results with 429 Omnifit total hips in 356 patients after a mean follow-up of 60 months. Time to revision and wear of the polyethylene liner with dif...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acta orthopaedica Scandinavica
دوره 58 6 شماره
صفحات -
تاریخ انتشار 1987