Relationship between functional residual capacity, respiratory compliance, and oxygenation in patients ventilated after cardiac surgery.

نویسندگان

  • Hermann Heinze
  • Beate Sedemund-Adib
  • Matthias Heringlake
  • Torsten Meier
  • Wolfgang Eichler
چکیده

BACKGROUND Measurement of functional residual capacity (FRC) is now possible at bedside, during mechanical ventilation. OBJECTIVES To determine the relationship of measured absolute and relative predicted FRC values to oxygenation and respiratory-system compliance, and to identify variables that influence FRC in ventilated patients after cardiac surgery. METHODS We retrospectively analyzed data from 99 patients ventilated after cardiac surgery. Each patient underwent an alveolar recruitment maneuver and was then ventilated with a positive end-expiratory pressure of 10 cm H2O and a tidal volume of 6-8 mL/kg predicted body weight. We measured quasi-static 2-point compliance of the respiratory system, FRC (with the oxygen-wash-out method), PaO2, and fraction of inspired oxygen (F(I)O2). We indexed the FRC values to predicted FRC reference values from sitting and supine healthy volunteers. RESULTS Correlation analyses revealed no meaningful association between FRC and PaO2/F(I)O2 (r2 0.20, P < .001). There was a moderate association between absolute FRC and respiratory-system compliance (r2 0.50, P < .001). Indexing the absolute measured FRC values to the predicted FRC values did not improve the correlation. We conducted multiple linear regression analyses of height, weight, age, sex, presence of mild chronic obstructive pulmonary disease, minute volume, and peak inspiratory pressure during ventilation, and revealed weight, minute volume, and peak inspiratory pressure (r2 = 0.65) as independent covariates of FRC. CONCLUSIONS Indexing the measured FRC values to the predicted supine and sitting FRC values does not improve the association between PaO2/F(I)O2 and respiratory-system compliance. In mechanically ventilated patients after cardiac surgery, FRC is influenced more by the ventilator settings than by physiologic variables (as in spontaneously breathing persons).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of cardiac rehabilitation exercises on functional capacity and Ejection fraction in patients after coronary artery bypass graft surgery

Aims: The use of rehabilitation programs is effective in heart patients. Therefore, the aim of the present study was to determination the effect of cardiac rehabilitation exercises on functional capacity and ejection fraction in patients after coronary artery bypass graft surgery. Materials & Methods: For this purpose, 16 cardiac patients of Fatemeh Zahra Sari heart center who underwent CABG s...

متن کامل

Changes in functional residual capacity during cardiac surgery.

A gas washout technique was used to measure the functional residual capacity (FRC) in eight patients during anaesthesia for cardiac surgery. The patients were anaesthetized with droperidol, fentanyl and nitrous oxide, alcuronium was given and the lungs were ventilated with a volume controlled ventilator. FRC was measured at three stages before skin incision, after sternotomy but before cardiopu...

متن کامل

The prone positioning during general anesthesia minimally affects respiratory mechanics while improving functional residual capacity and increasing oxygen tension.

We investigated the effects of the prone position on the mechanical properties (compliance and resistance) of the total respiratory system, the lung, and the chest wall, and the functional residual capacity (FRC) and gas exchange in 17 normal, anesthetized, and paralyzed patients undergoing elective surgery. We used the esophageal balloon technique together with rapid airway occlusions during c...

متن کامل

Dead space fraction changes during PEEP titration following lung recruitment in patients with ARDS.

BACKGROUND Elevated dead space fraction (the ratio of dead space to tidal volume [V(D)/V(T)]) is a feature of ARDS. PEEP can partially reverse atelectasis, prevent alveoli recollapse, and improve lung compliance and gas exchange in patients with ARDS. However, whether V(D)/V(T) variables have a close relationship with PEEP and collapse alveolar recruitment remains under recognized. Meanwhile, f...

متن کامل

Specific compliance and gas exchange during high-frequency oscillatory ventilation.

OBJECTIVES To evaluate the use of specific compliance (static compliance/functional residual capacity) to adjust mean airway pressure, resulting in optimal gas exchange during high-frequency oscillatory ventilation in a surfactant-deficient newborn piglet. DESIGN Prospective controlled animal study. SETTING Laboratory. SUBJECTS Eight newborn piglets at 5 days of age. BACKGROUND High-fre...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 55 5  شماره 

صفحات  -

تاریخ انتشار 2010