Desorption electrospray ionization-mass spectrometry of proteins.
نویسندگان
چکیده
Desorption electrospray ionization-mass spectrometry (DESI-MS) was evaluated for the detection of proteins ranging in molecular mass from 12 to 66 kDa. Proteins were uniformly deposited on a solid surface without pretreatment and analyzed with a DESI source coupled to a quadrupole ion trap mass spectrometer. DESI-MS parameters optimized for protein detection included solvent flow rate, temperature of heated capillary tube, incident and reflection angle, sheath gas pressure, and ESI voltage. Detection limits were obtained for all protein standards, and they were found to decrease with decreasing protein molecular mass: for cytochrome c (12.3 kDa) and lysozyme (14.3 kDa) a detection limit of 4 ng/mm2 was obtained; for apomyoglobin (16.9 kDa) 20 ng/mm2; for beta-lactoglobulin B (18.2 kDa) 50 ng/mm2; and for chymotrypsinogen A (25.6 kDa) 100 ng/mm2. The DESI-MS analysis of higher molecular mass proteins such as ovalbumin (44.4 kDa) and bovine serum albumin (66.4 kDa) yielded mass spectra of low signal-to-noise ratio, making their detection and molecular weight determination difficult. In this study, DESI-MS proved to be a rapid and robust method for accurate MW determination for proteins up to 17 kDa under ambient conditions. Finally, we demonstrated the DESI-MS detection of the bacteriophage MS2 capsid protein from crude samples with minimal sample preparation.
منابع مشابه
Imaging of Proteins in Tissue Samples Using Nanospray Desorption Electrospray Ionization Mass Spectrometry.
Chemical maps of tissue samples provide important information on biological processes therein. Recently, advances in tissue imaging have been achieved using ambient ionization techniques, such as desorption electrospray ionization mass spectrometry (DESI-MS), but such techniques have been almost exclusively confined to the mapping of lipids and metabolites. We report here the use of nanospray d...
متن کاملReversed phase liquid chromatography hyphenated to continuous flow-extractive desorption electrospray ionization-mass spectrometry for analysis and charge state manipulation of undigested proteins.
The application of continuous flow-extractive desorption electrospray ionization (CF-EDESI), an ambient ionization source demonstrated previously for use with intact protein analysis, is expanded here for the coupling of reversed phase protein separations to mass spectrometry. This configuration allows the introduction of charging additives to enhance detection without affecting the chromatogra...
متن کاملUltrasound ionization of biomolecules.
To date, mass spectrometric analysis of biomolecules has been primarily performed with either matrix-assisted laser desorption/ionization (MALDI) or electrospray ionization (ESI). In this work, ultrasound produced by a simple piezoelectric device is shown as an alternative method for soft ionization of biomolecules. Precursor ions of proteins, saccharides and fatty acids showed little fragmenta...
متن کاملCoupling desorption electrospray ionization with ion mobility/mass spectrometry for analysis of protein structure: evidence for desorption of folded and denatured States.
A desorption electrospray ionization (DESI) source has been coupled to an ion mobility time-of-flight mass spectrometer for the analysis of proteins. Analysis of solid-phase horse heart cytochrome c and chicken egg white lysozyme proteins with different DESI solvents and conditions shows similar mass spectra and charge state distributions to those formed when using electrospray to analyze these...
متن کاملCoupling of liquid chromatography with mass spectrometry by desorption electrospray ionization (DESI).
A liquid chromatography/mass spectrometry (LC/MS) method using desorption electrospray ionization (DESI) as a versatile interface has been established, which allows a wide range of elution flow rates, online derivatization via reactive DESI and further combination with electrochemistry.
متن کاملNon-proximate detection of explosives and chemical warfare agent simulants by desorption electrospray ionization mass spectrometry.
Desorption electrospray ionization (DESI) mass spectrometry is used for the selective and sensitive detection of trace amounts of explosives and chemical warfare agent simulants from ambient surfaces at distances of up to 3 meters from the mass spectrometer.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 79 9 شماره
صفحات -
تاریخ انتشار 2007