Rapid method for the analysis of plutonium isotopes in a soil sample within 60 min.
نویسندگان
چکیده
A rapid method for the determination of Pu isotopes in a soil sample within 60 min of starting sample pretreatment was developed. The large reduction in the analysis time was attained by the rapid and perfect digestion of the sample using an alkaline fusion method with an induction heating machine. Pu concentrations were then determined by flow injection/ICP-MS using a solid extraction resin after preconcentration by batch extraction with a chelate resin. The limits of detection for 239Pu and 240Pu were 9.2 fg and 4.3 fg, corresponding to 0.03 and 0.05 Bq kg(-1), respectively, under our analytical conditions, which satisfy the lower detection limits (0.5 Bq kg(-1) of 239Pu, and 2 Bq kg(-1) of 240Pu) required for rapid analysis techniques by the Ministry of Education, Culture, Sports, Science and Technology, Japan. This method provides a powerful and practical technique for emergency monitoring in and around nuclear facilities that handle large amounts of plutonium.
منابع مشابه
Rapid method for plutonium-241 determination in soil samples
A simple and rapid procedure for the determination of plutonium isotopes in the environment is presented. The procedure combines alpha spectrometry, solvent extraction and liquid scintillation measurements to ensure that both alpha- and beta-emitting isotopes are determined. Of five tested extractants, bis-(2-ethylhexyl) phosphoric acid was found to be the best choice. The procedure was applied...
متن کاملRapid Extraction of Plutonium from Urine by Pyrosulfate Fusion and PERALS Spectroscopy
Rapid Extraction of Plutonium from Urine by Pyrosulfate Fusion and PERALS Spectroscopy R.L. Metzger, P.H. Pouquette, and G.W. Klingler Radiation Safety Engineering, Inc. Chandler, AZ Abstract To effectively treat accident victims exposed to airborne isotopes of Plutonium, chelation therapy must be started before the Plutonium is fixed in bone. Urine bioassay samples must be processed rapidly af...
متن کاملRadiochemical Analysis of Pu , U and Sr Isotopes in Soil Samples with
Recently, several studies have reported on combined procedures for the determination of radionuclides in soils or sediment samples with extraction chromatographic materials such as the TRU, Sr and TEVA Spec resins. These methods are somewhat difficult to apply for very low levels of fallout radionuclides without using large amounts of extraction chromatographic resin. Therefore, it is necessary...
متن کاملDevelopment of rapid plutonium analysis for environmental samples by isotope dilution/inductively coupled plasma mass spectrometry with on-line column.
This paper describes our development of a rapid on-line column/ID-ICP-MS technique for the analysis of plutonium (Pu) in environmental samples using an UTEVA extraction chromatograph resin (UTEVA resin) column. It took only 40 min to separate and measure Pu in the sample solution, including the time for conditioning the resin column for the next analysis. In our method, Pu in a 3 M nitric acid ...
متن کاملIsotopic analysis of uranium and plutonium using ICP-MS and estimation of burn-up of spent uranium in contaminated environmental samples{
Environmental monitoring of actinides and evaluation of the contamination source (nuclear weapons tests, nuclear power plant and nuclear reprocessing plant accidents, etc.) requires precise and accurate isotopic analysis of actinides, especially uranium and plutonium. Double-focusing sector-field inductively coupled plasma mass spectrometry (ICP-SFMS) using a low-flow microconcentric nebulizer ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 22 2 شماره
صفحات -
تاریخ انتشار 2006