Quantitative coronary angiographic and intravascular ultrasound assessment of a new nonarticulated stent: report from the Advanced Cardiovascular Systems MultiLink stent pilot study.

نویسندگان

  • J P Carrozza
  • J B Hermiller
  • T J Linnemeier
  • J J Popma
  • P G Yock
  • G S Roubin
  • L S Dean
  • R E Kuntz
  • L Robertson
  • K K Ho
  • D E Cutlip
  • D S Baim
چکیده

OBJECTIVES The purpose of this study was to evaluate the safety, feasibility, optimal deployment technique and 1-year clinical outcome for the Advanced Cardiovascular Systems (ACS) MultiLink stent. BACKGROUND Optimal stent deployment assessed by quantitative coronary angiography and intravascular ultrasound (IVUS) is associated with improved clinical outcome. METHODS Forty-nine consecutive patients with a discrete stenosis in a native coronary artery 3 to 4 mm in diameter were treated with the new, balloon-expandable ACS MultiLink stent. Stent expansion was assessed in all patients using quantitative coronary angiography and serial IVUS imaging after 8-, 12- and 16-atm inflations. Clinical follow-up was obtained at 30 days and 1 year. RESULTS All 49 patients had successful placement of a MultiLink stent without death, emergency coronary artery bypass graft surgery or Q wave myocardial infarction. After placement of the MultiLink stent, the minimal lumen diameter increased from 1.24 to 2.98 mm (p < 0.001), and diameter stenosis decreased from 61% to 7% (p = 0.001). Minimal lumen cross-sectional area by IVUS increased progressively after 8, 12 and 16 atm (5.6 to 6.8 to 7.4 mm2, respectively, p < 0.001). However, only 64% of stents achieved a lumen/reference area ratio > or = 70%. No adverse clinical events occurred by 30 days, and by 1 year only one patient (2.0%) required revascularization of the stented artery. CONCLUSIONS Treatment of stenoses in native coronary arteries with the MultiLink stent is associated with a high success rate and a low incidence of adverse events by 1 year, despite the fact that the majority of stents did not meet IVUS-defined criteria for "optimal stenting" derived from first-generation devices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Early- and long-term intravascular ultrasound and angiographic findings after bioabsorbable magnesium stent implantation in human coronary arteries.

OBJECTIVES This study aimed to evaluate the degradation rate and long-term vascular responses to the absorbable metal stent (AMS). BACKGROUND The AMS demonstrated feasibility and safety at 4 months in human coronary arteries. METHODS The PROGRESS-AMS (Clinical Performance and Angiographic Results of Coronary Stenting) was a prospective, multicenter clinical trial of 63 patients with coronar...

متن کامل

Safety, Efficacy and Clinical Outcome of Direct Stent Implantation

Conventional methods of stenting require predilatation, which potentially increase vessel wall injury and cost of the procedure. In this study, the safety and efficacy of direct AVE-S7 (Medtronic-USA) stent placement were evaluated in 100 patients. Quantitative coronary angiography was performed at the baseline and post-stent. Clinical follow-up was done up to 9 months. In 100 patients (76 male...

متن کامل

Two-year clinical, angiographic, and intravascular ultrasound follow-up of the XIENCE V everolimus-eluting stent in the treatment of patients with de novo native coronary artery lesions: the SPIRIT II trial.

BACKGROUND This article reports the 2-year clinical, angiographic, and intravascular ultrasound outcomes of the everolimus-eluting stent (EES) compared with the paclitaxel-eluting stent (PES) in the randomized SPIRIT II trial. METHODS AND RESULTS This was a prospective, single-blind clinical trial in which a total of 300 patients with de novo native coronary artery lesions were randomized to ...

متن کامل

Intracoronary ultrasound observations during stent implantation.

T he Palmaz-Schatz stent has been used successfully to improve primary angioplasty results, to treat large coronary dissections, or to prevent impending closure of the lumen.-1-5 The determination of successful stent implantation is based on the angiographic appearance. However, angiographic projection imaging may not reveal the three-dimensional geometry that is necessary to appreciate full ex...

متن کامل

StentBoost Visualization for the Evaluation of Coronary Stent Expansion During Percutaneous Coronary Interventions

INTRODUCTION Inadequate stent implantation is associated with stent thrombosis and restenosis. StentBoost can enhance stent visualization and evaluate stent expansion. Currently, there are limited comparison studies between StentBoost and intravascular ultrasound (IVUS). We aimed to test the correlation and agreement between IVUS and StentBoost measurements. METHODS From December 2010 to Dece...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 31 1  شماره 

صفحات  -

تاریخ انتشار 1998