QSRR application to two-dimensional gas chromatography
نویسندگان
چکیده
Gas chromatography (GC) and two-dimensional GC (GC-GC) are widely used for separation, structure elucidation and quantitative analysis. In GC and GC-GC, the chemical structure is elucidated by comparing the measured retention time of each compound with the database. But, structure elucidation is infeasible when the retention time is not available from the database. Thus, quantitative structure retention relationship (QSRR) is proposed to predict the retention time from the structure. Some researchers constructed the QSRR models specialized for the limited types of compounds. In this study, we aim to construct the QSRR models that can predict the retention time of various compounds in GC-GC with high accuracy. In addition, we propose a structure elucidation method based on the inverse analysis with the models. First, the objective value of the retention time is set. Then, structure elucidation is accomplished by comparing the objective value with the predicted retention time of new structures. The prediction errors can be a problem in comparison between the predicted and objective values. We deal with this problem by setting an acceptable error for each compound based on the reliability of the predicted value. The analysis with the measurement data proved the effectiveness of the proposed method.
منابع مشابه
An improved structure models to explain retention behavior of atmospheric nanoparticles
The quantitative structure-retention relationship (QSRR) of nanoparticles in roadside atmosphere against the comprehensive two-dimensional gas chromatography which was coupled to high-resolution time-of-flight mass spectrometry was studied. The genetic algorithm (GA) was employed to select the variables that resulted in the best-fitted models. After the variables were selected, the linear multi...
متن کاملComparison of Weighting Schemes for Molecular Graph Descriptors: Application in Quantitative Structure-Retention Relationship Models for Alkylphenols in Gas-Liquid Chromatography
Organic compounds containing heteroatoms or multiple bonds can be conveniently represented as vertex- and edge-weighted molecular graphs. These atom and bond parameters can be computed for any organic compound with two parameter sets that we have recently defined, namely, the relative electronegativity X and the relative covalent radius Y weighting schemes. Structural descriptors computed with ...
متن کاملQuantitative structure—retention relationship analysis of nanoparticle compounds
Genetic algorithm and partial least square (GA-PLS), the kernel PLS (KPLS) and Levenberg-Marquardt artificial neural network (L-M ANN) techniques were used to investigate the correlationbetween retention time (RT) and descriptors for 15 nanoparticle compounds which obtained by thecomprehensive two dimensional gas chromatography system (GC x GC). Application of thedodecanethiol monolayer-protect...
متن کاملPrediction of Linear Retention Index of Teucrium chamaedrys Volatiles in GC×GC-TOF/MS by Linear Model
Genetic algorithm and partial least square (GA-PLS) technique was used to investigate the correlation between linear retention index (LRI) for Teucrium chamaedrys volatiles which were obtained by direct thermal desorption (DTD) technique with comprehensive two-dimensional (2D) gas chromatography-time-of-flight mass spectrometry (GC×GC-TOF/MS). The applied internal (leave-group-out cross validat...
متن کاملFast Determination of Denatured Fuel Ethanol Purity by Two-Dimensional Gas Chromatography Application
Two-dimensional gas chromatography not only provides improved resolution, it can also provide much faster analysis times. A two-dimensional gas chromatography system based on a simplified Deans switch design is used to analyze the alcohol content in denatured fuel grade ethanol. By using two short columns of different selectivity, the two-dimensional gas chromatography application completes thi...
متن کامل