Enhanced UV inactivation of adenoviruses under polychromatic UV lamps.

نویسندگان

  • Karl G Linden
  • Jeanette Thurston
  • Raymond Schaefer
  • James P Malley
چکیده

Adenovirus is recognized as the most UV-resistant waterborne pathogen of concern to public health microbiologists. The U.S. EPA has stipulated that a UV fluence (dose) of 186 mJ cm(-2) is required for 4-log inactivation credit in water treatment. However, all adenovirus inactivation data to date published in the peer-reviewed literature have been based on UV disinfection experiments using UV irradiation at 253.7 nm produced from a conventional low-pressure UV source. The work reported here presents inactivation data for adenovirus based on polychromatic UV sources and details the significant enhancement in inactivation achieved using these polychromatic sources. When full-spectrum, medium-pressure UV lamps were used, 4-log inactivation of adenovirus type 40 is achieved at a UV fluence of less than 60 mJ cm(-2) and a surface discharge pulsed UV source required a UV fluence of less than 40 mJ cm(-2). The action spectrum for adenovirus type 2 was also developed and partially explains the improved inactivation based on enhancements at wavelengths below 230 nm. Implications for water treatment, public health, and the future of UV regulations for virus disinfection are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spectral sensitivity of Bacillus subtilis spores and MS2 coliphage for validation testing of ultraviolet reactors for water disinfection.

The microbicidal UV fluence under polychromatic radiation from UV lamps is typically measured using the DNA absorbance spectrum as a weighting factor for the relative wavelength effectiveness. However, this DNA-based weighting does not necessarily match the spectral sensitivity of the microorganism being tested. Bacillus subtilis spores are often used for UV reactor validation in Europe, while ...

متن کامل

Molecular indications of protein damage in adenoviruses after UV disinfection.

Adenoviruses are resistant to monochromatic, low-pressure (LP) UV disinfection--but have been shown to be susceptible to inactivation by polychromatic, medium-pressure (MP) UV--when assayed using cell culture infectivity. One possible explanation for the difference between UV lamp types is that the additional UV wavelengths emitted by MP UV enable it to cause greater damage to viral proteins th...

متن کامل

Endotoxin inactivation in water by using medium-pressure UV lamps.

Deionized water was spiked with various concentrations of endotoxin and exposed to UV irradiation from medium-pressure UV lamps to assess endotoxin inactivation. It was found that endotoxin inactivation was proportional to the UV dose under the conditions examined. The inactivation rate was determined to be approximately 0.55 endotoxin unit/ml per mJ/cm(2) of irradiation delivered.

متن کامل

UV disinfection of adenoviruses: molecular indications of DNA damage efficiency.

Adenovirus is a focus of the water treatment community because of its resistance to standard, monochromatic low-pressure (LP) UV irradiation. Recent research has shown that polychromatic, medium-pressure (MP) UV sources are more effective than LP UV for disinfection of adenovirus when viral inactivation is measured using cell culture infectivity assays; however, UV-induced DNA damage may be rep...

متن کامل

Challenge Organisms for Inactivation of Viruses by Ultraviolet Treatment

BACKGROUND: Ultraviolet reactors that are used for drinking water disinfection need to be tested to ensure they are delivering the required doses and achieving the desired level of pathogen inactivation to protect public health. Testing methods can use biological, chemical, or particle surrogates, although not all approaches have been approved for reactor validation. The non-pathogenic bacterio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied and environmental microbiology

دوره 73 23  شماره 

صفحات  -

تاریخ انتشار 2007