Variation of nerve fibre layer thickness measurements with age and ethnicity by scanning laser polarimetry.
نویسندگان
چکیده
AIMS Scanning laser polarimetry is a new technique allowing quantitative analysis of the retinal nerve fibre layer in vivo. This technique was employed to investigate the variation of the retinal nerve fibre layer thickness in a group of normal subjects of different ages and ethnic groups. METHODS 150 normal volunteers of different ages and ethnic groups were recruited for this study. Three consecutive 15-degree polarimetric maps were acquired for each subjects. Nerve fibre layer thickness measurements were obtained at 1.5 disc diameters from the optic nerve. Four 90-degree quadrants were identified. RESULTS The mean nerve fibre layer thickness varied from a minimum of 55.4 microns to a maximum of 105.3 microns, with a mean thickness value of 78.2 (SD 10.6) microns. Superior and inferior quadrants showed a comparatively thicker nerve fibre layer than nasal and temporal quadrants. Retinal nerve fibre layer thickness is inversely correlated with age (p < 0.001). White people showed thicker nerve fibre layers than Afro-Caribbeans (p = 0.002). CONCLUSION The results indicate a progressive reduction of the nerve fibre layer thickness with increasing age. This may be due to a progressive loss of ganglion axons with age as suggested in postmortem studies. A racial difference in nerve fibre layer thickness is present between whites and Afro-Caribbeans.
منابع مشابه
Scanning laser polarimetry of the retinal nerve fibre layer in primary open angle and capsular glaucoma.
AIMS To evaluate the clinical value of scanning laser polarimetry with the nerve fibre analyser type II in primary open angle glaucoma (POAG) and capsular glaucoma. METHODS Scanning laser polarimetry was performed on one eye of 30 patients suffering from POAG, 25 patients suffering from capsular glaucoma, and on 35 healthy control subjects. The retinal nerve fibre layer (RNFL) thickness value...
متن کاملComparative study of the retinal nerve fibre layer thickness performed with optical coherence tomography and GDx scanning laser polarimetry in patients with primary open-angle glaucoma
BACKGROUND We compared the parameters of retinal nerve fibre layer in patients with advanced glaucoma with the use of different OCT (Optical Coherence Tomograph) devices in relation to analogical measurements performed with GDx VCC (Nerve Fiber Analyzer with Variable Corneal Compensation) scanning laser polarimetry. MATERIAL/METHODS Study subjects had advanced primary open-angle glaucoma, pre...
متن کاملAxonal loss from acute optic neuropathy documented by scanning laser polarimetry.
BACKGROUND/AIMS Retinal nerve fibre layer analysis by scanning laser polarimetry has been shown to facilitate diagnosis of glaucoma while its role in glaucoma follow up is still unclear. A major difficulty is the slow reduction of retinal nerve fibre layer thickness in glaucomatous optic neuropathy. Eyes of patients were studied after acute retrobulbar optic nerve lesion in order to evaluate th...
متن کاملEvaluating the optic nerve and retinal nerve fibre layer: the roles of Heidelberg retina tomography, scanning laser polarimetry and optical coherence tomography.
INTRODUCTION For many years, ophthalmologists have looked at the optic nerve head to evaluate the status of glaucoma. Clinical examination of the optic nerve head and retinal nerve fibre layer (RNFL) is however, subjective and sometimes variable. Recent developments in computer-based imaging technologies have provided a means of obtaining quantitative measurements of the optic nerve head topogr...
متن کاملRelation of optic disc topography and age to thickness of retinal nerve fibre layer as measured using scanning laser polarimetry, in normal subjects.
AIMS To evaluate the relation of the optic nerve head topographic measurements and age with the thickness of the retinal nerve fibre layer (RNFL) in normal Caucasoid subjects by means of scanning laser polarimetry and tomography. METHODS Topographic optic disc measurements and RNFL thickness values of 38 normal Caucasoid subjects of both sexes aged 20 to 78 were measured using a confocal scan...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 81 5 شماره
صفحات -
تاریخ انتشار 1997