Ophthalmodynamometry for ICP prediction and pilot test on Mt. Everest

نویسندگان

  • Henry W Querfurth
  • Philip Lieberman
  • Steve Arms
  • Steve Mundell
  • Michael Bennett
  • Craig van Horne
چکیده

BACKGROUND A recent development in non-invasive techniques to predict intracranial pressure (ICP) termed venous ophthalmodynamometry (vODM) has made measurements in absolute units possible. However, there has been little progress to show utility in the clinic or field. One important application would be to predict changes in actual ICP during adaptive responses to physiologic stress such as hypoxia. A causal relationship between raised intracranial pressure and acute mountain sickness (AMS) is suspected. Several MRI studies report that modest physiologic increases in cerebral volume, from swelling, normally accompany subacute ascent to simulated high altitudes. OBJECTIVES 1) Validate and calibrate an advanced, portable vODM instrument on intensive patients with raised intracranial pressure and 2) make pilot, non-invasive ICP estimations of normal subjects at increasing altitudes. METHODS The vODM was calibrated against actual ICP in 12 neurosurgical patients, most affected with acute hydrocephalus and monitored using ventriculostomy/pressure transducers. The operator was blinded to the transducer read-out. A clinical field test was then conducted on a variable data set of 42 volunteer trekkers and climbers scaling Mt. Everest, Nepal. Mean ICPs were estimated at several altitudes on the ascent both across and within subjects. RESULTS Portable vODM measurements increased directly and linearly with ICP resulting in good predictability (r = 0.85). We also found that estimated ICP increases normally with altitude (10 ± 3 mm Hg; sea level to 20 ± 2 mm Hg; 6553 m) and that AMS symptoms did not correlate with raised ICP. CONCLUSION vODM technology has potential to reliably estimate absolute ICP and is portable. Physiologic increases in ICP and mild-mod AMS are separate responses to high altitude, possibly reflecting swelling and vasoactive instability, respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A theoretical model to allow prediction of the CSF pressure from observations of the retinal venous pulse.

PURPOSE There is no easy way to estimate the intracranial pressure (ICP) noninvasively. The retinal vein can exhibit large amplitude oscillations at the level of the lamina cribrosa under certain circumstances. The aims of this study were to develop a theoretical understanding of the conditions required to establish this vigorous oscillatory behavior and to determine whether observations of it ...

متن کامل

Update in intracranial pressure evaluation methods and translaminar pressure gradient role in glaucoma.

Glaucoma is one of the leading causes of blindness worldwide. Historically, it has been considered an ocular disease primary caused by pathological intraocular pressure (IOP). Recently, researchers have emphasized intracranial pressure (ICP), as translaminar counter pressure against IOP may play a role in glaucoma development and progression. It remains controversial what is the best way to mea...

متن کامل

Effects on colour discrimination during long term exposure to high altitudes on Mt Everest.

AIM To investigate changes in colour discrimination as a result of chronic hypoxic exposure induced by extreme altitudes (above 8000 m) during an expedition to Mt Everest. METHODS Colour discrimination thresholds for tritan, protan and deutan axes were measured extensively in two male participants (four eyes) during an expedition to Mt Everest, using a quantitative, computer controlled psycho...

متن کامل

Recent increase in black carbon concentrations from a Mt. Everest ice core spanning 18602000 AD

[1] A Mt. Everest ice core spanning 1860–2000 AD and analyzed at high resolution for black carbon (BC) using a Single Particle Soot Photometer (SP2) demonstrates strong seasonality, with peak concentrations during the winter‐ spring, and low concentrations during the summer monsoon season. BC concentrations from 1975–2000 relative to 1860–1975 have increased approximately threefold, indicating ...

متن کامل

Surpassing Mt. Everest: extreme flight performance of alpine bumble-bees.

Animal flight at altitude involves substantial aerodynamic and physiological challenges. Hovering at high elevations is particularly demanding from the dual perspectives of lift and power output; nevertheless, some volant insects reside and fly at elevations in excess of 4000 m. Here, we demonstrate that alpine bumble-bees possess substantial aerodynamic reserves, and can sustain hovering fligh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2010