Streptococci from primary isolation plates grouped by reverse passive haemagglutination.
نویسندگان
چکیده
Reverse passive haemagglutination, a novel microtitre based assay, was compared with the Streptex (Wellcome UK) latex slide agglutination kit for streptococcal grouping in a diagnostic microbiology laboratory. Three hundred and fifty two extracts from 349 consecutive primary isolation plates were assayed by both methods. Reverse passive haemagglutination gave identical grouping results for 98.0% of the 345 streptococci identified by Streptex, and the kappa coefficient of agreement between the methods for all 352 extracts tested was 0.973. Cross reactions with Listeria spp seen with Streptex were not found by reverse passive haemagglutination. In the reverse passive haemagglutination method 11 streptococci could be grouped on each 96-well plate and most reactions were stable for at least 30 minutes. Reverse passive haemagglutination is more rapid to perform than latex slide agglutination when many organisms are to be grouped, and the patterns of haemagglutination are easily recognised. If the method was taken into routine use in a diagnostic laboratory, the persistence of reverse passive haemagglutination reactions would enable grouping results to be checked for quality control purposes.
منابع مشابه
Reverse passive haemagglutination test for the rapid identification of Neisseria gonorrhoeae and detection of penicillinase production.
In a comparison of the reverse passive haemagglutination test (RPHA) with the direct immunofluorescent and rapid carbohydrate utilisation tests for the identification of Neisseria gonorrhoeae isolated from clinical specimens, 315 isolates of oxidase-positive Gram-negative diplococci were tested as pure 24-hour-old subcultures and samples from 108 similar organisms were taken directly from prima...
متن کاملLaboratory evaluation of a rapid four-hour serological grouping of groups A,B,C, and G beta-streptococci by the Phadebact streptococcus test.
Grouping of beta-hemolytic streptococcal isolates by staphylococcal coagglutination was performed with the Phadebact Streptococcus Test to determine whether such isolates could be accurately grouped serologically with 4 h after examination of the primary isolation plates. Of 132 clinical isolates, 131 were correctly grouped by the Phadebact method using the Lancefield precipitation method as th...
متن کاملA sensitive single reverse passive haemagglutination test for detecting both HBsAg and anti-HBs.
A trial of a modified reverse passive haemagglutination test for HBsAg using a 0.1% cell suspension instead of the recommended 1% showed an approximately eight-fold increase in detection sensitivity. The test can be performed within 30 minutes and lends itself to mass screening techniques. Confirmation tests can be done using the 0.1% method. In addition, the same serological plates and cells u...
متن کاملEvaluation of an improved Streptex kit for the grouping of beta-haemolytic streptococci by agglutination.
A modified Streptex kit in which the extraction procedure had been simplified was used to group 200 streptococcal strains. Positive reactions could be obtained with live colonies and over 90% of isolates were correctly grouped from primary isolation plates. Some minor cross-reactions were seen with Streptex, but these were not strong enough to cause any confusion and no isolates were incorrectl...
متن کاملComparison of Meritec-Strep with Streptex for direct colony grouping of beta-hemolytic streptococci from primary isolation and subculture plates.
Meritec-Strep (Meridian Diagnostics, Inc., Cincinnati, Ohio) a coagglutination method, was compared with Streptex (Wellcome Diagnostics, Research Triangle Park, N.C.), a latex agglutination method, for the identification of beta-hemolytic streptococcal groups A, B, C, F, and G by the direct colony method. A total of 124 beta-hemolytic streptococcal isolates were tested, which included 77 from g...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical pathology
دوره 44 8 شماره
صفحات -
تاریخ انتشار 1991