Ion-selective electrode studies on the effects of 5-hydroxytryptamine on the intracellular level of potassium in an insect salivary gland.
نویسندگان
چکیده
Potassium-sensitive microelectrodes were used to measure the intracellular level of potassium in Calliphora salivary glands. During stimulation with 1 X 10(-8) M 5-HT, the potassium concentration increased from a resting level of 133.2 to 139.0 mM. When the external concentration of potassium was reduced below 2mM there was a rapid loss of potassium which could be partially reversed by 5-HT. During 5-HT stimulation, the addition of ouabain had no effect on a number of parameters including the rate of fluid secretion, the ionic composition of the saliva and the intracellular level of potassium. The possibility that potassium enters the cells passively is discussed.
منابع مشابه
Construction of an Ion-Selective Eelectrode for Determination of permanganate Ion
A PVC ion-selective membrane electrode based on Cd-tetraphenyl porphyrine as a carrier was prepared fordetermination of MnO4- ion. This electrode revealed good selectivity toward permanganate ion over a widevariety of anions. Effects of some experimental parameters such as nature of the plasticizer, the amounts ofcarrier and additive, and concentration of the internal solution on the potential ...
متن کاملDetermination of Copper Content of Human Blood Plasma by an Ion Selective Electrode based on a New Copper-Selectophore
A new selectophore was introduced for Cu2+ ions. Spectroscopic studies showed a selectivity of a new organic compound (L) toward copper ions and several transitional metal ions. Hence, L was utilized in designing several ion selective electrodes for these cations. In practice, Cu2+ ion selective electrode behaved Nernstian (slope of 27.95±0.3 mV decade-1) over a...
متن کاملDetermination of Cobalt(II) by a New PVC Membrane Coated Graphite Electrode Based on 6-chloro-11- azabenzo[a]phenothiazin-5-one as a neutral ion carrier
Cobalt has great biological effects on human beings and also other living organisms, hence its determination is very important. In this regard, a novel coated graphite electrode was designed for determination of Co2+ ions by exploiting 6-chloro-11- azabenzo[a]phenothiazin-5-one as a neutral ion carrier, for the first time. The foremost function was witnessed from the membrane composition of PVC...
متن کاملElectron microprobe and ion-selective microelectrode studies of fluid secretion in the salivary glands of Calliphora.
1. The concentrations of sodium, potassium, chloride and water in the cells, secretory canaliculi and the lumen of Calliphora salivary glands have been measured by microprobe analysis of frozen-hydrated sections. Free concentrations of K+ and Cl~ in all three compartments were measured with ion-selective microelectrodes. 2. Most of the quantitative data from the two techniques are in close agre...
متن کاملEffect of Berberis vulgaris Aqueous Extract on the Apoptosis, Sodium and Potassium in Hepatocarcinogenic Rats
Objective(s) The effect of Berberis vulgaris aqueous extract in hepatocarcinogenic rats was studied to investigate the apoptotic and sodium, potassium elements properties. A loss of both intracellular potassium and sodiumoccurs when apoptotic cells shrink and prior to the loss of membraneintegrity. Materials and Methods Forty-eight Sprague dawley rats were randomly divided into 2 groups, normal...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of experimental biology
دوره 72 شماره
صفحات -
تاریخ انتشار 1978