Impact of prosthesis-patient mismatch on survival after mitral valve replacement.
نویسندگان
چکیده
BACKGROUND We recently reported that valve prosthesis-patient mismatch (PPM) is associated with persisting pulmonary hypertension after mitral valve replacement. Thus, the objective of this study was to evaluate the impact of PPM on mortality in patients undergoing mitral valve replacement. METHODS AND RESULTS The indexed valve effective orifice area was estimated for each type and size of prosthesis being implanted in 929 consecutive patients and used to define PPM as not clinically significant if > 1.2 cm2/m2, as moderate if > 0.9 and < or = 1.2 cm2/m2, and as severe if < or = 0.9 cm2/m2. Moderate PPM was present in 69% of patients; severe PPM was seen in 9%. For patients with severe PPM, 6-year survival (74+/-5%) and 12-year survival (63+/-7%) were significantly less than for patients with moderate PPM (84+/-1% and 76+/-2%; P=0.027) or nonsignificant PPM (90+/-2% and 82+/-4%; P=0.002). On multivariate analysis, severe PPM was associated with higher mortality (hazard ratio, 3.2; 95% confidence interval, 1.5 to 6.8; P=0.003). CONCLUSIONS Severe PPM is an independent predictor of mortality after mitral valve replacement. As opposed to other independent risk factors, PPM may be avoided or its severity may be reduced with the use of a prospective strategy at the time of operation. For patients identified as being at risk for severe PPM, every effort should be made to implant a prosthesis with a larger effective orifice area.
منابع مشابه
Enlargement of mitral valve ring in a young woman with severe prosthesis-patient mismatch.
Mechanical prosthesis is the first choice for valve replacement at the mitral position in children. Replacement of the original prosthesis because of prosthesis-patient mismatch (PPM) is almost inevitable when prostheses are implanted in small children. The impact of PPM on long-term mortality becomes significant when the effective orifice area (EOA) is severely reduced. In these cases prosthes...
متن کاملImpact of prosthesis-patient mismatch after mitral valve replacement in rheumatic population: Does mitral position prosthesis-patient mismatch really exist?
BACKGROUND Prosthesis-patient mismatch (PPM) is characterised by the effects of inadequate prosthesis size relative to body surface area (BSA).The purpose of this study was to determine the impact of PPM on late clinical outcomes after mitral valve replacement (MVR) in rheumatic population. METHODS From 2000 to 2013, a total of 445 patients (mean age 54.2 ± 11.7 years) underwent isolated MVR ...
متن کامل[Influence of patient-prosthesis mismatch in the octogenarian undergoing surgery for aortic valve replacement due to severe stenosis].
INTRODUCTION AND OBJECTIVES The clinical impact of patient-prosthesis mismatch on the outcome in octogenarians who undergo surgery for aortic valve replacement due to severe stenosis is unknown. Our objective was to quantify the frequency of some degree of patient-prosthesis mismatch and its impact on mortality and life quality. METHODS We analyzed all the octogenarian patients who underwent ...
متن کاملImpact of valve prosthesis-patient mismatch on pulmonary arterial pressure after mitral valve replacement.
OBJECTIVES We sought to determine the impact of valve prosthesis-patient mismatch (PPM) on pulmonary arterial (PA) pressure after mitral valve replacement (MVR). BACKGROUND Pulmonary arterial hypertension is a serious complication of mitral valve disease, and it is a major risk factor for poor outcome after MVR. We hypothesized that valve PPM might be a determinant of PA hypertension after MV...
متن کاملSuccessful Use of Two Thrombolytic Drugs in Prosthetic Mitral and Aortic Valve Thrombosis
Introduction: Prosthetic valve thrombosis is a rare and severe complication of valve replacement, most often encountered with a mechanical prosthesis. The significant morbidity and mortality associated with this condition warrant rapid diagnostic evaluation. Although surgery is the first-line therapy in symptomatic obstructive mechanical valve thrombosis, thrombolytic therapy has been used as a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chinese medical journal
دوره 126 19 شماره
صفحات -
تاریخ انتشار 2007