Diffracted wavefront measurement of a volume phase holographic grating at cryogenic temperature.
نویسندگان
چکیده
Flatness of the wavefront diffracted by grating can be mandatory for some applications. At ambient temperature, the wavefront diffracted by a volume phase holographic grating (VPHG) is well mastered by the manufacturing process and can be corrected or shaped by postpolishing. However, to be used in cooled infrared spectrometers, VPHGs have to stand and work properly at low temperatures. We present the measurement of the wavefront diffracted by a typical VPHG at various temperatures down to 150 K and at several thermal inhomogeneity amplitudes. The particular grating observed was produced using a dichromated gelatine technique and encapsulated between two glass blanks. Diffracted wavefront measurements show that the wavefront is extremely stable according to the temperature as long as the latter is homogeneous over the grating stack volume. Increasing the thermal inhomogeneity increases the wavefront error that pinpoints the importance of the final instrument thermal design. This concludes the dichromated gelatine VPHG technology, used more and more in visible spectrometers, can be applied as it is to cooled IR spectrometers.
منابع مشابه
Citation for Published Item: Use Policy Cryogenic Tests of Volume-phase Holographic Gratings: Results at 100 K
We present results from cryogenic tests of Volume-Phase Holographic (VPH) gratings at ∼ 100 K. The aims of these tests are to see whether the diffraction efficiency as a function of wavelength is significantly different at a low temperature from that at room temperature and to see how the performance of a VPH grating is affected by a number of thermal cycles. We have completed 10 cycles between...
متن کاملar X iv : a st ro - p h / 03 11 51 7 v 1 2 2 N ov 2 00 3 Cryogenic Tests of Volume - Phase Holographic Gratings : I . Results at 200 K
We present results from cryogenic tests of a Volume-Phase Holographic (VPH) grating at 200 K measured at near-infrared wavelengths. The aims of these tests were to see whether the diffraction efficiency and angular dispersion of a VPH grating are significantly different at a low temperature from those at a room temperature, and to see how many cooling and heating cycles the grating can withstan...
متن کاملCryogenic tests of volume-phase holographic gratings: results at 100 K.
We present results from cryogenic tests of volume-phase holographic (VPH) gratings at approximately 100 K. The aims of these tests are to see whether the diffraction efficiency as a function of wavelength is significantly different at a low temperature from that at room temperature and to see how the performance of a VPH grating is affected by a number of thermal cycles. We have completed ten c...
متن کاملar X iv : a st ro - p h / 06 09 06 9 v 1 4 Se p 20 06 Cryogenic tests of volume - phase holographic gratings : results at 100 K
We present results from cryogenic tests of Volume-Phase Holographic (VPH) gratings at ∼ 100 K. The aims of these tests are to see whether the diffraction efficiency as a function of wavelength is significantly different at a low temperature from that at room temperature and to see how the performance of a VPH grating is affected by a number of thermal cycles. We have completed 10 cycles between...
متن کاملQuasi-collinear and partially degenerate four-wave mixing: an alternative explanation of the phase-conjugation property of backward stimulated scattering
A quasi-collinear and partially degenerate four-wave mixing model is proposed to explain the optical phase-conjugation property of various types of stimulated backscattering. According to this model, after passing through a phase-disturbed medium or an aberration plate, the input pump beam can be resolved into two portions: a stronger undisturbed regular portion and a weaker phase-disturbed irr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied optics
دوره 45 27 شماره
صفحات -
تاریخ انتشار 2006