Evaluation of a maximum likelihood procedure for measuring pure-tone thresholds under computer control.
نویسندگان
چکیده
An adaptive, maximum likelihood (ML) procedure was assessed as an automated tool for estimating audiometric pure-tone thresholds in the clinic under computer control. Pure-tone air-conduction thresholds were measured from 101 workmen who received annual hearing rechecks as part of their employee hearing conservation program. A pure-tone threshold was measured bilaterally for each of the standard audiometric frequencies in a 15-trial block to yield 60 percent correct detection with the ML procedure. The workmen were tested on a modified "yes-no" task. On a trial, the signal was presented in a visually cued 200-msec observation interval. Each workman then had 1000 msec to make a "yes" response. If the workman did not respond during the 1000-msec response period, then the computer assumed a "no" response. After either the "yes" or "no" response, the computer adjusted the signal level for the next trial. The thresholds measured by ML procedure compared favorably with thresholds measured from the same listeners by conventional (CONV) audiometry. The efficiency of the ML procedure was also compared in terms of the time necessary for an experienced audiologist to instruct the listener and perform CONV audiometry. CONV audiometry (3-4 minutes per listener) required about half of the time needed for the ML procedure (6-7 minutes per listener). The relatively longer time associated with measuring an audiogram with the ML procedure was due primarily to more trials being used to estimate threshold.
منابع مشابه
بررسی دقت تخمین آستانه شنوایی بهنجار بوسیله پاسخهای برانگیخته قشر شنوایی
Background: Cortical Evoked Response Audiometry (CERA) refers to prediction of behavioral pure-tone thresholds (500-4000 Hz) obtained by recording the N1-P2 complex of auditory long latency responses. CERA is the preferred method for frequency–specific estimation of audiogram in conscious adults and older children. CERA has an increased accuracy of determination of the hearing thresholds of ale...
متن کاملتأثیر مواجهه با نویز بر سیستم شنوایی کارگران با استفاده از ادیومتری تون خالص (PTA)، گسیلهای صوتی گذرای گوش (TEOAEs) و گسیلهای صوتی محصول اعوجاج (DPOAE)
Background: Different studies have shown that Otoacoustic Emission (OAEs) is generated by Outer Hair Cells (OHCs) and these sensory cells are first structures exposed to damage of high level noise. Therefore minor impairment in OHCs can lead to lack of response of OAE. The purpose of the current study is to compare the pure tone thresholds, Transient Evoked Otoacoustic Emission (TEOAE...
متن کاملیافتههای پاسخ برانگیخته پایدار شنوایی در بزرگسالان مبتلا به نوروپاتی/ناهمزمانی شنوایی
Background & Aim: Auditory steady state response(ASSR) is an auditory evoked response that has received a lot of attention nowadays. At present, ASSR is mostly used to estimate pure-tone thresholds. Clinical evidence of ASSR in combination with findings for auditory middle latency response (AMLR) and 40 Hz response support the assumption that based on stimulus modulation rate, the ASSR anat...
متن کاملEffect of Exposure to a Mixture of Organic Solvents on Hearing Thresholds in Petrochemical Industry Workers
Introduction: Hearing loss is one of the most common occupational diseases. In most workplaces, workers are exposed to noise and solvents simultaneously, so the potential risk of hearing loss due to solvents may be attributed to noise. In this study we aimed to assess the effect of exposure to mixed aromatic solvents on hearing in the absence of exposure to hazardous noise. Materials and Met...
متن کاملComparative study between pure tone audiometry and auditory steady-state responses in normal hearing subjects.
INTRODUCTION Auditory steady-state responses (ASSR) are an important tool to detect objectively frequency-specific hearing thresholds. Pure-tone audiometry is the gold-standard for hearing evaluation, although sometimes it may be inconclusive, especially in children and uncooperative adults. AIM Compare pure tone thresholds (PT) with ASSR thresholds in normal hearing subjects. MATERIALS AND...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the American Academy of Audiology
دوره 7 2 شماره
صفحات -
تاریخ انتشار 1996