Total hip arthroplasty with acetabular fixation: an unexpected complication.
نویسنده
چکیده
The incidence of vascular injuries associated with total hip arthroplasty (THA) is low. However, several vascular structures are at risk of injury within the pelvis. These include the external iliac, femoral, and obturator vessels. Both reaming of the acetabulum and drilling of the acetabular screw holes may place these structures at risk. If left untreated, injuries to these vessels may be associated with severe morbidity and mortality. In this report, an acute vascular complication that had an unusual presentation is highlighted. A 72-year-old woman presented to the emergency department following a road traffic accident in which she sustained a combined fracture of the right acetabulum and femoral head. Her treatment involved a combination of THA and pelvic open reduction and internal fixation. The immediate perioperative recovery period was uncomplicated. However, the patient developed a deep venous thrombus in her right calf 7 days after surgery. Further investigation revealed a second thrombus, occluding the right common femoral vein. Surgical exploration revealed that a screw placed during the initial surgery was pressing against the vessel and occluding it. The discrepancy in incidence between the development of deep venous thrombosis and vascular compression or injury means that the association between the 2 events is unlikely to be made. The author highlights this unusual presentation to improve early recognition and prompt management of similar cases. The importance of adequate preoperative planning and intraoperative imaging with a C-arm is also stressed.
منابع مشابه
Pelvic Discontinuity Caused by Acetabular Overreaming during Primary Total Hip Arthroplasty
Intraoperative acetabular fracture is a rare complication of primary total hip arthroplasty (THA), typically occurring during impaction of the cementless acetabular component. Here we report an unusual case of pelvic discontinuity caused by overreaming of the acetabulum during primary THA. Restoration of posterior columnar continuity was achieved with an autologous fibular graft and a reconstru...
متن کاملCementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs
Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...
متن کاملEarly Clinical Outcomes with a 3-D Porous Titanium Acetabular Cup
Cementless acetabular components are associated with a significant incidence of polyethylene wear and secondary osteolysis. 3-dimentional (3-D) porous coating and enhanced shell to a liner fixation are expected to reduce the polyethylene wear and to increase the longevity of an acetabular cup. The authors report the early clinical outcome with a cementless acetabular cup, Regenerex Ringloc+ (Zi...
متن کاملAcetabular Reconstruction in Total Hip Arthroplasty
The difficulties encountered in dealing with the bone deficient acetabulum are amongst the greatest challenges in hip surgery. Acetabular reconstruction in revision total hip arthroplasty can successfully be achieved with hemispherical components featuring a porous or roughened ingrowth surface and options for placement of multiple screws for minor acetabular defect. Acetabular component select...
متن کاملNavigated Acetabular Cup Fixation for Acetabular Deformity or Revision Total Hip Arthroplasty
PURPOSE To evaluate the usefulness of navigated acetabular cup fixation for total hip arthroplasty in patients with acetabular deformity or revision total hip arthroplasty. MATERIALS AND METHODS This study enrolled 28 patients with at least 12 months' follow-up. The safe zone of the acetabular cup was defined as 40°±10°in inclination and 15°±10°in anteversion. The authors used the navigation ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Orthopedics
دوره 38 5 شماره
صفحات -
تاریخ انتشار 2014