Recalculation of an artificially released avalanche with SAMOS and validation with measurements from a pulsed Doppler radar
نویسنده
چکیده
A joint experiment was carried out on 10 February 1999 by the Swiss Federal Institute for Snow and Avalanche Research (SFISAR) and the Austrian Institute for Avalanche and Torrent Research (AIATR, of the Federal Office and Research Centre for Forests, BFW) to measure forces and velocities at the full scale experimental site CRÊTA BESSE in VALLÉE DE LA SIONNE, Canton du Valais, Switzerland. A huge avalanche could be released artificially, which permitted extensive investigations (dynamic measurements, improvement of measurement systems, simulation model verification, design of protective measures, etc.). The results of the velocity measurements from the dual frequency pulsed Doppler avalanche radar of the AIATR and the recalculation with the numerical simulation model SAMOS are explained in this paper.
منابع مشابه
Next level for snow pack monitoring in real-time using Ground-Penetrating Radar (GPR) technology
Currently available snow pack monitoring methods are limited due to spatial resolution or to adequate weather and secure avalanche conditions. Snow pack monitoring is impossible if the method is destructive as snow probing and thereby the use for avalanche forecasts limited. Ultrasonic snow height sensors are not feasible for an application in snow deposition areas along ridges or in avalanche ...
متن کاملISAR Image Improvement Using STFT Kernel Width Optimization Based On Minimum Entropy Criterion
Nowadays, Radar systems have many applications and radar imaging is one of the most important of these applications. Inverse Synthetic Aperture Radar (ISAR) is used to form an image from moving targets. Conventional methods use Fourier transform to retrieve Doppler information. However, because of maneuvering of the target, the Doppler spectrum becomes time-varying and the image is blurred. Joi...
متن کاملStudy of Cardiac Parameters by Pulsed Wave Doppler Echocardiography in Normal Healthy Markhoz Goat
Objective- The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy Markhoz goats.Design- Retrospective study.Animals- 20 female Markhoz goats.Procedure- Using a standardized PW Doppler echocardiographic protocol, 20healthy adult unsedated female Markhoz goats were investigated three times at one-...
متن کاملNormal left ventricular systolic time intervals assessed by pulsed wave Doppler echocardiography in the Turkmen horse of Iran
The Turkmen horse is one of the oldest and purest breeds in the world. There is no information with regards to the normal echocardiographic parameters of this horse regarding to cardiac diseases. Pulsed-wave (PW) Doppler echocardiography was performed on 42 clinically normal 3- to 15-year-old racing Turkmen horses. There were 26 stallions and 16 mares. The left ventricular isovolumetric contrac...
متن کاملExtending the Radar Dynamic Range using Adaptive Pulse Compression
The matched filter in the radar receiver is only adapted to the transmitted signal version and its output will be wasted due to non-matching with the received signal from the environment. The sidelobes amplitude of the matched filter output in pulse compression radars are dependent on the transmitted coded waveforms that extended as much as the length of the code on both sides of the target loc...
متن کامل