White blood cell differentiation using a solid state flow cytometer.

نویسندگان

  • R M Doornbos
  • E J Hennink
  • C A Putman
  • B G De Grooth
  • J Greve
چکیده

A flow cytometer using a solid state light source and detector was designed and built. For illumination of the sample stream two types of diode lasers (670 nm and 780 nm) were tested in a set-up designed to differentiate human leukocytes by means of light scattering. The detector is an avalanche photodiode, which was used to detect the weak scattered light in the orthogonal direction. The new flow cytometer set-up is very small, relatively cheap and yields similar results as a standard flow cytometer set-up using a helium-neon laser and photomultipliers.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cluster of Differentiation 45: An Adjunct to Flowcytometric Diagnosis of Leukemias

Background: This Cross sectional comparative study was performed to compare the mean fluorescence intensity of cluster of differentiation 45 between healthy individuals and patients with acute lymphoblastic leukemia. Patients and methods: Thirty three healthy individuals (mean age 11 years) and 41 patients with B cell acute lymphoblastic leukemia (mean age 7 years) were enrolled in the study...

متن کامل

Four-parameter white blood cell differential counting based on light scattering measurements.

Measurement of the depolarized orthogonal light scattering in flow cytometry enables one to discriminate human eosinophilic granulocytes from neutrophilic granulocytes. We use this method to perform a four-parameter differential white blood cell analysis. A simple flow cytometer was built equipped with a 5-mW helium neon laser that measures simultaneously four light scattering parameters. Lymph...

متن کامل

Four-part Differential Leukocyte Count Using Flow Cytometer

This paper reports the four-part differential leukocyte count (DLC) of human blood using a MEMS microflow (flow) cytometer. It is achieved with a two-color laser-induced fluorescence (LIF) detection scheme. Four types of leukocytes including neutrophils, eosinophils, lymphocytes and monocytes are identified in blood samples, which are stained by fluorescein isothiocyanate (FITC) and propidium ...

متن کامل

Leukocyte analysis and differentiation using high speed microfluidic single cell impedance cytometry.

Miniature high speed label-free cell analysis systems have yet to be developed, but have the potential to deliver fast, inexpensive and simple full blood cell analysis systems that could be used routinely in clinical practice. We demonstrate a microfluidic single cell impedance cytometer that performs a white blood cell differential count. The device consists of a microfluidic chip with micro-e...

متن کامل

Unsatisfactory performance of flow cytometer UF-100 and urine strips in predicting outcome of urine cultures.

UF-100 flow cytometer and urine strip results were cross-interpreted to predict culture outcomes. The best negative predictive value was obtained with bacteria at > or =1,000/microl, white blood cells at > or =20/microl, or leukocyte esterase positivity. Nine of 24 false negatives were clinically significant. Thus, UF-100 and urine strip results do not accurately predict the outcome of cultures.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Cytometry

دوره 14 6  شماره 

صفحات  -

تاریخ انتشار 1993