Acute detection of ST-elevation myocardial infarction missed on standard 12-Lead ECG with a novel 80-lead real-time digital body surface map: primary results from the multicenter OCCULT MI trial.

نویسندگان

  • James W Hoekstra
  • Brian J O'Neill
  • Yuri B Pride
  • Cedric Lefebvre
  • Deborah B Diercks
  • W Frank Peacock
  • Gregory J Fermann
  • C Michael Gibson
  • Duane Pinto
  • Jim Giglio
  • Abhinav Chandra
  • Charles B Cairns
  • Marvin A Konstam
  • Joe Massaro
  • Mitchell Krucoff
چکیده

STUDY OBJECTIVE Although 80-lead ECG body surface mapping is more sensitive for ST-elevation myocardial infarction (STEMI) than the 12-lead ECG, its clinical utility in chest pain in the emergency department (ED) has not been studied. We sought to determine the prevalence, clinical care patterns, and clinical outcomes of patients with STEMI identified on 80-lead but not on 12-lead (80-lead-only STEMI). METHODS The Optimal Cardiovascular Diagnostic Evaluation Enabling Faster Treatment of Myocardial Infarction trial was a multicenter prospective observational study of moderate- to high-risk chest pain patients presenting to the ED. Patients received simultaneous 12-lead and 80-lead ECGs as part of their initial evaluation and were treated according to the standard of care, with clinicians blinded to the 80-lead results. The primary outcome of the trial was door-to-sheath time in patients with 80-lead-only STEMI versus patients with STEMI identified by 12-lead alone (12-lead STEMI). Secondary outcomes included angiographic and clinical outcomes at 30 days. RESULTS One thousand eight hundred thirty patients were evaluated, 91 had a discharge diagnosis of 12-lead STEMI, and 25 patients met criteria for 80-lead-only STEMI. Eighty-four of the 91 12-lead STEMI patients underwent cardiac catheterization, with a median door-to-sheath time of 54 minutes, versus 14 of the 25 80-lead-only STEMI patients, with a door-to-sheath time of 1,002 minutes (estimated treatment difference in median=881; 95% confidence interval 181 to 1,079 minutes). Clinical outcomes and revascularization rates, however, were similar between 80-lead-only STEMI and 12-lead STEMI patients. CONCLUSION The 80-lead ECG provides an incremental 27.5% increase in STEMI detection versus the 12-lead. Patients with 80-lead-only STEMI have adverse outcomes similar to those of 12-lead STEMI patients but are treated with delayed or conservative invasive strategies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The relation of ST segment deviations in 12-lead conventional Electrocardiogram, right and posterior leadswith the site of oc-clusion in acute inferior myocardial infarction

  Background :In addition to diagnosing the acute myocardial infarction (MI), stratifying high-risk patients and proper treatment strategies are important issues in managing patients complaining of chest pain and suspecting MI. Many studies have been conducted to predict the occlusion site by interpreting the ST segment deviations in Electrocardiogram (ECG).Additional posterior and right precor...

متن کامل

Prehospital and interhospital delay in the treatment of patients with acute myocardial infarction with ST segment elevation and strategies to improve it from the perspective of the process owners: The importance of time

Introduction: Fibrinolytic drugs are one of the important strategies for the treatment of patients with acute myocardial infarction with ST segment elevation, especially in small centers. This study was conducted with the aim of evaluating the distance with the global standard for fibrinolytic treatment and the viewpoints of experts in this regard. Materials and Methods: This cross-sectional st...

متن کامل

Non-ST-Segment Elevation Myocardial Infarction: A Novel and Robust Approach for Early Detection of Patients at Risk

N on-ST-elevation myocardial infarction (NSTEMI) is lower on the severity spectrum of acute coronary syndromes than is myocardial infarction (MI), resulting from complete occlusion of a major coronary artery. As the name implies, it is a syndrome that does not exhibit the dramatic ST elevation observed in the standard 12-lead ECG in chest pain patients with confirmed acute MI. The important cli...

متن کامل

Usefulness of three posterior chest leads for the detection of posterior wall acute myocardial infarction.

A significant proportion of patients with myocardial infarction are missed upon initial presentation to the emergency department. The 12-lead electrocardiogram (ECG) has a low sensitivity for the detection of acute myocardial infarction, especially if the culprit lesion is in the left circumflex artery (LCA). This study was designed to evaluate the benefit of adding 3 posterior chest leads on t...

متن کامل

No-Reflow Phenomenon in Patients with ST-Elevation Acute Myocardial Infarction, Treated with Primary Percutaneous Coronary Intervention: A Study of Predictive Factors

  Introduction: No-reflow phenomenon in coronary vessels, manifested in some patients with reperfused acute myocardial infarction (MI), is associated with poor clinical and functional outcomes. Therefore, evaluation of predisposing risk factors can be helpful in risk assessment and identification of patients at higher risk. Herein, we aimed to study the predictive factors for the development of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of emergency medicine

دوره 54 6  شماره 

صفحات  -

تاریخ انتشار 2009