High-energy photons in IMRT: uncertainties and risks for questionable gain.

نویسندگان

  • J S Welsh
  • T R Mackie
  • J P Limmer
چکیده

For a start, although integral dose is generally assumed to be improved by the use of higher energy photons, there is concern that some treatment planning systems might not effectively model the “beam narrowing” at depth observed with high energy photons in the small radiation beamlets encountered in IMRT. This phenomenon is caused by lateral beam degradation due to penumbra widening (8); when very small fields are used, there is greater loss of electron equilibrium laterally with higher energy photons (8, 9). This is especially problematic at high gradients, leading to dose reduction near the beam edge and along the central axis (10). The clinical solution to this problem is to use wider beams – which negates the hypothetical gain from high-energy photons as far as integral dose is concerned.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of high energy photon beam in dose- volume parameters and integral dose of normal structures in Head and neck IMRT

Introduction: The aim of this study is to investigate the effect of partially used high photon energies on dosimetric parameters and integral doses of nasopharynx IMRT plans.   Materials and Methods: Two 7 coplanar IMRT plan were created for eleven patients (6 MV only IMRT plan in both phase1 and phase2 and 6 MV phase1-mixed energies (6 MV and 15 MV) phase2...

متن کامل

Second primary cancers after radiation for prostate cancer: a review of data from planning studies

A review of planning studies was undertaken to evaluate estimated risks of radiation induced second primary cancers (RISPC) associated with different prostate radiotherapy techniques for localised prostate cancer. A total of 83 publications were identified which employed a variety of methods to estimate RISPC risk. Of these, the 16 planning studies which specifically addressed absolute or relat...

متن کامل

Rapid radiographic film calibration for IMRT verification using automated MLC fields.

A method for measuring a film sensitometric curve using a single sheet of film exposed with a two field step-and-shoot MLC treatment was developed and tested with Kodak XV2 and EDR2 films. With this technique a film sensitometric curve can be completed in only 10 minutes, making it practical to generate new film calibrations daily. This method is applicable to film calibrations for all purposes...

متن کامل

3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis

 Background: To analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (IMRT) and 3 dimensional conformal radiotherapy (3DCRT) and selection of optimal photon energy for IMRT treatments. Material and methods: 24 patients with localized prostate carcinoma were planned for 3DCRT and IMRT techniques. Radiation dose of 54 Gy with 2 Gy/fraction, was planned to ...

متن کامل

Characterization of low, medium and high energy collimators for common isotopes in nuclear medicine: A Monte Carlo study

Introduction:In an ideal parallel-hole collimator, thickness of septal material should be sufficient to stop more than 95% of incident photons. However, some photons pass the septa without interaction or experience scattering before they reach the detector. In this study, we determined different contribution of collimator responses consist of geometrical response, septal penetr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Technology in cancer research & treatment

دوره 6 2  شماره 

صفحات  -

تاریخ انتشار 2007