Control of Pedicle Screw Placement with an Electrical Conductivity Measurement Device: Initial Evaluation in the Thoracic and Lumbar Spine
نویسندگان
چکیده
Aim. Transpedicular screw fixation is widely used in spinal surgery. But the insertion of pedicle screws can sometimes be challenging because of the variability in pedicle size and the proximity of nerve roots. Methods. We detected intraoperatively the sensitivity for iatrogenic pedicel perforation with a hand-held electronic conductivity measurement device (ECD) that measures electrical conductivity of tissue-medium surrounding the instrument tip. ECD was used to guide the placement of 84 pedicle screws in 15 patients undergoing surgery for tumor or degenerative spinal disease at various spinal levels from T8 to L5. Additionally a CT-scan controlled screw positioning postoperatively. Results. The placement was "correct" (no mediocaudal pedicle wall penetration) for 78 of 84 (92,8%) screws, "suboptimal but acceptable" (0-2 mm penetration) for 4 of 84 (4,8%) screws, and "misplaced" (penetration > 2 mm) for 2 of 84 (2,4%) screws. Conclusion. Although this study was not designed to compare electronic conductivity technique to other guidance methods, such as fluoroscopy or navigation, a convincing "proof of concept" for ECD use in spinal instrumentation could be demonstrated. Advantages include easy handling without time-consuming setup and reduced X-ray exposure. However, further investigations are necessary to evaluate i.a. the economic aspects for this single-use developed instrument.
منابع مشابه
Accuracy Assessment of Freehand Pedicular Screw Placement
Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...
متن کاملReduction in radiation (fluoroscopy) while maintaining safe placement of pedicle screws during lumbar spine fusion.
STUDY DESIGN Prospective, randomized, controlled study. OBJECTIVE To report the results of using the PediGuard (SpineGuard, Inc., San Francisco, CA), a local electrical conductivity measurement device, to reduce radiation exposure while drilling the pilot hole for pedicle screw placement. SUMMARY OF BACKGROUND DATA Reports of pedicle screw placement in the lumbar spine have shown medial ped...
متن کاملPosterior thoracic segmental pedicle screw instrumentation: evolving methods of safe and effective placement.
The use of pedicle screw instrumentation in the spine has evolved over the last two decades. The initial use of pedicle screws began in the lumbar spine. As surgeons have become more comfortable with the complex anatomy required for accurate screw placement, the use of pedicle instrumentation has evolved to include their use in the thoracolumbar and thoracic spine. The impetus behind their incr...
متن کاملComparison of the pedicle screws placement between electronic conductivity device and normal pedicle finder in posterior surgery of scoliosis.
STUDY DESIGN Prospective randomized clinical trial. OBJECTIVE To compare the accuracy and time using of pedicle screw placement between electronic conductivity device (ECD) and normal pedicle finder (NPF) in posterior surgery of scoliosis, through a randomized clinical trial. SUMMARY OF BACKGROUND DATA Pedicle screw insertion for scoliosis correction can be associated with increased pedicle...
متن کاملComputer-assisted pedicle screw placement for thoracolumbar spine fracture with separate spinal reference clamp placement and registration.
BACKGROUND The objective of the study was to improve the accuracy of computer-assisted pedicle screw installation in the spine. This study evaluates the accuracy of computer-assisted pedicle screw placement with separate spinal reference clamp placement and registration on each instrumented vertebra for thoracolumbar spine fractures. METHODS Postoperative radiographs and CT scans assessed the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
دوره 2016 شماره
صفحات -
تاریخ انتشار 2016