Hearing screening for school children: utility of noise-cancelling headphones

نویسندگان

  • Ada Hiu Chong Lo
  • Bradley McPherson
چکیده

BACKGROUND Excessive ambient noise in school settings is a major concern for school hearing screening as it typically masks pure tone test stimuli (particularly 500 Hz and below). This results in false positive findings and subsequent unnecessary follow-up. With advances in technology, noise-cancelling headphones have been developed that reduce low frequency noise by superimposing an anti-phase signal onto the primary noise. This research study examined the utility of noise-cancelling headphone technology in a school hearing screening environment. METHODS The present study compared the audiometric screening results obtained from two air-conduction transducers-Sennheiser PXC450 noise-cancelling circumaural headphones (NC headphones) and conventional TDH-39 supra-aural earphones. Pure-tone hearing screening results (500 Hz to 4000 Hz, at 30 dB HL and 25 dB HL) were obtained from 232 school children, aged 6 to 8 years, in four Hong Kong primary schools. RESULTS Screening outcomes revealed significant differences in referral rates between TDH-39 earphones and NC headphones for both 30 dB HL and 25 dB HL criteria, regardless of the inclusion or exclusion of 500 Hz results. The kappa observed agreement (OA) showed that at both screening intensities, the transducers' referral agreement value for the 500 Hz inclusion group was smaller than for the 500 Hz exclusion group. Individual frequency analysis showed that the two transducers screened similarly at 1000 Hz and 2000 Hz at 25 dB HL, as well as at both 30 dB HL and 25 dB HL screening levels for 4000 Hz. Statistically significant differences were found for 500 Hz at 30 dB HL and at 25 dB HL, and for 1000 Hz and 2000 Hz at 30 dB HL. OA for individual frequencies showed weaker intra-frequency agreement between the two transducers at 500 Hz at both intensity criterion levels than at higher frequencies. CONCLUSIONS NC headphones screening results differed from those obtained from TDH-39 earphones, with lower referral rates at 500 Hz, particularly at the 25 dB HL criterion level. Therefore, NC headphones may be able to operate at lower screening intensities and subsequently increase pure-tone screening test sensitivity, without compromising specificity. NC headphones show some promise as possible replacements for conventional earphones in school hearing screening programs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Smartphone hearing screening with integrated quality control and data management.

OBJECTIVE To determine if a smartphone application could be used as a calibrated screening audiometer with real-time noise monitoring for school screening using automated test sequences. DESIGN The investigation comprised three studies. Study 1 evaluated calibration accuracy across four Samsung S5301 smartphones (Android v4.0.4) using commercial Sennheiser HD202 headphones. Study 2 involved r...

متن کامل

The effect of noise-cancelling headphones or music on pain perception and anxiety in men undergoing transrectal prostate biopsy.

OBJECTIVE To assess the effect of noise-cancelling headphones with or without music on patient pain and anxiety associated with routine, office-based transrectal ultrasound (TRUS)-guided prostate biopsy in a prospective randomized study. METHODS Patients scheduled for prostate biopsy as a result of elevated prostate-specific antigen and/or abnormal digital rectal examination were prospectivel...

متن کامل

Comparison of school-based hearing screening protocols and the identification of noise induced hearing loss in adolescents

School-based hearing screening programs have been commonplace in the United States since the 1960’s. Historically, the enrollment of children in the public school system afforded the first opportunity to have access to a large population of children in order to screen for hearing disorders. Such programs were primarily designed to identify hearing losses that necessitated medical referral and t...

متن کامل