HeartMate II left ventricular assist device; early European experience.

نویسندگان

  • Martin Strüber
  • Kare Sander
  • Jaap Lahpor
  • Henrik Ahn
  • Pierre-Yves Litzler
  • Stavros G Drakos
  • Francesco Musumeci
  • Christian Schlensak
  • Ivar Friedrich
  • Ronny Gustafsson
  • Frank Oertel
  • Pascal Leprince
چکیده

OBJECTIVE The novel axial flow left ventricular assist device HeartMate II was introduced into clinical practice in Europe as part of the pilot study and after CE approval in November 2005. In order to get an overview of the use and performance of the device in Europe a group of investigators was founded to compare the initial results. METHODS In a retrospective analysis of the first 101 consecutive cases in Europe, data were collected with regard to postoperative outcome and severe adverse events and anticoagulation protocols. Results were stratified by intention to treat as a bridge to transplant or as chronic support therapy in heart failure (destination therapy). RESULTS In 70% of patients, the HeartMate II was intended as a bridge to transplant therapy, in 30%, it was used as a destination therapy device. The perioperative mortality post implant was 20% in the bridge to transplant patients and 7% in the destination therapy arm. However, after 1 year a comparable survival was observed in both groups (69% destination therapy, 63% bridge to transplant). Main causes of death were multiple organ failure (n=12) and cerebrovascular accidents (n=5). All, but one cerebrovascular accident occurred in the first 9 days after surgery. Only one other death was reported thereafter and there was no mechanical failure of the device. CONCLUSIONS Even in the early experience the HeartMate II was used as a chronic support device in a substantial number of patients in Europe. Although the total experience is still limited, the incidence of cerebrovascular accidents is very low and the survival beyond the perioperative period is excellent.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Right heart dysfunction after left ventricular assist device implantation: a comparison of the pulsatile HeartMate I and axial-flow HeartMate II devices.

BACKGROUND Right heart dysfunction confers significant morbidity and mortality after left ventricular assist device implantation and historically occurs in as many as a third of patients. It is unknown whether newer axial flow pumps have a different impact on postimplant right heart dysfunction. We compared the incidence of right heart dysfunction after implantation of the pulsatile HeartMate I...

متن کامل

Thyrotoxicosis-facilitated bridge to recovery with a continuous-flow left ventricular assist device.

The HeartMate II is a continuous-flow left ventricular assist device that can be explanted from patients after cardiac recovery. We implanted a HeartMate II in a 21-year-old man who had idiopathic cardiomyopathy. A year later, he developed thyrotoxicosis, presumably secondary to amiodarone administered for ventricular fibrillation. Four months after the diagnosis of thyrotoxicosis, thyroid horm...

متن کامل

Editorial comment: Adverse events in long-term ventricular assist device therapy.

the higher risk of developing a thrombosis anyway. In conclusion, compared with the other study results, our data suggest that a notably mild anticoagulation protocol does not increase the risk of severe thrombo-embolic events in the early and late postoperative period after the implantation of the HM II CW LVAD. Furthermore, this mild regime is helpful in reducing the still unacceptably high i...

متن کامل

Acquired von Willebrand syndrome after exchange of the HeartMate XVE to the HeartMate II ventricular assist device.

Instead of pulsatile ventricular assist devices an increasing number of nonpulsatile ventricular assist devices are introduced to clinical practice. The different flow characteristics of this new technique lead to alteration in shear stress on blood components, which may affect the coagulation system. Repeated von Willebrand factor analyses were performed in a patient who first was implanted wi...

متن کامل

Survival after left ventricular assist device with and without temporary right ventricular support.

BACKGROUND Right ventricular (RV) failure after the insertion of a left ventricular assist device (LVAD) historically results in poor outcomes. Patients requiring temporary RV support after LVAD insertion are a heterogeneous group of patients consisting of those in cardiogenic shock after myocardial infarction, to those with chronic decompensated heart failure. For patients requiring biventricu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 34 2  شماره 

صفحات  -

تاریخ انتشار 2008