Accuracy evaluation of ITCsF2: a nitrogen cooled caesium fountain

نویسندگان

  • Filippo Levi
  • Davide Calonico
  • Claudio E Calosso
  • Aldo Godone
  • Salvatore Micalizio
  • Giovanni A Costanzo
چکیده

For almost two decades, caesium fountain primary frequency standards (PFS) have represented the best realization of the definition of the second in the International System of units. Their accuracy has progressively improved with time, reaching a few parts in 1016. In this paper, we present the accuracy evaluation of ITCsF2, the new Cs fountain PFS developed at the Italian National Metrological Institute, designed to be operated at cryogenic temperature to reduce the blackbody radiation shift. The short-term stability of the ITCsF2 fountain is 2 × 10−13τ−1/2 when operated at high atomic density, and the relative inaccuracy reaches 2.3 × 10−16. We also report four calibrations of International Atomic Time with a relative frequency agreement of (−1.7 ± 3.2)× 10−16, between ITCsF2 and the average of the other fountains operated in the world during the reference periods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

First accuracy evaluation of NIST-F2

We report the first accuracy evaluation of NIST-F2, a second-generation laser-cooled caesium fountain primary standard developed at the National Institute of Standards and Technology (NIST) with a cryogenic (liquid nitrogen) microwave cavity and flight region. The 80 K atom interrogation environment reduces the uncertainty due to the blackbody radiation shift by more than a factor of 50. Also, ...

متن کامل

Accuracy evaluation of NIST-F1

The evaluation procedure of a new laser-cooled caesium fountain primary frequency standard developed at the National Institute of Standards and Technology (NIST) is described. The new standard, NIST-F1, is described in some detail and typical operational parameters are discussed. Systematic frequency biases for which corrections are made – second-order Zeeman shift, black-body radiation shift, ...

متن کامل

Realisation of a Frequency Standard Using an Atomic Fountain *

We report the realisation and preliminary study of a frequency standard using a fountain of laser cooled caesium atoms. Our apparatus uses a magneto-optical trap as a source of cold atoms and optical pumping to prepare the atoms in the correct state before they enter the microwave cavity.

متن کامل

Uncertainty evaluation of the caesium fountain clock PTB-CSF2

The uncertainty evaluation of CSF2, the second caesium fountain primary frequency standard at PTB, is presented. The fountain uses optical molasses to cool atoms down to 0.6μK. The atoms are launched vertically in a moving optical molasses, and state-selected in the |F = 3,mF = 0〉 hyperfine ground state. During their ballistic flight, the atoms interact twice with a microwave field, thus comple...

متن کامل

Cancellation of the collisional frequency shift in caesium fountain clocks.

We have observed that the collisional frequency shift in primary caesium fountain clocks varies with the clock state population composition and, in particular, is zero for a given fraction of the |F=4,mF=0) atoms, depending on the initial cloud parameters. We present a theoretical model explaining our observations. The possibility of the collisional shift cancellation implies an improvement in ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014