Anterior knee symptoms after S-ROM hinge implantation.

نویسندگان

  • David J Deehan
  • Rajkumar Gangadharan
  • Ajay Malviya
  • Alasdair Sutherland
  • James P Holland
چکیده

PURPOSE To evaluate the performance of a canal filling hinge device for complex knee arthroplasty. METHODS Thirty-seven (4 primary hinge implantation and 33 revision cases) patients who had undergone arthroplasty with the S-ROM third generation hinge device for a combination of massive bone loss or ligamentous insufficiency were prospectively examined with a minimum of 5-year follow-up. Median age at surgery was 72 years (range: 43 to 87 years). Principal indications included aseptic loosening or massive osteolysis (24 cases), infection (8 cases) and periprosthetic fracture (4 cases). All patients exhibited either grade 2 (N = 12) or grade 3 (N = 25) AORI bone loss or a grade 3 medial ligament deficiency. RESULTS One patient experienced implant failure (71 months), and one patient suffered late deep infection (36 months). Mean WOMAC score improved from 27 to 62. Four patients required patellar resurfacing for persistent pain. The 5-year survivorship was 86%. CONCLUSIONS While the S-ROM device may offer satisfactory medium term outcome for complex end stage knee disease, we report a high rate of debilitating anterior knee symptoms.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Midterm Results of a New Rotating Hinge Knee Implant: A 5-Year Follow-Up

Background In the current study, we investigated midterm results of a new rotating hinge total knee arthroplasty (EnduRo prosthesis), which uses a new bearing material (CFR PEEK). Methods We prospectively analysed data of 50 patients with a minimum follow-up of 5 years. In 24 (48%) patients, a primary implantation was performed and 26 (52%) were revision cases. Clinical and radiographic exami...

متن کامل

Hinged external fixation of the knee: intrinsic factors influencing passive joint motion.

OBJECTIVE To measure changes in knee kinematics after the application of articulated external fixators along a previously described knee flexion/extension axis and 16 specific "off-axis" fixator hinge configurations. DESIGN Cadaver, biomechanical study. SETTING Biomechanics laboratory. PARTICIPANTS Nine fresh cadaver knee specimens. INTERVENTION Each specimen was mounted on a custom-bui...

متن کامل

Total knee arthroplasty using the S-ROM mobile-bearing hinge prosthesis.

A retrospective study was performed on 15 patients receiving 16 S-ROM mobile-bearing hinge total knee prostheses that were evaluated with at least a 2-year follow-up (range, 27-71 months). Indications for its use included severe instability and bone loss. The average patient age was 63 years (range, 33-83 years). There were 15 revision arthroplasties and 1 primary arthroplasty. Knee Society sco...

متن کامل

Early Results of a New Rotating Hinge Knee Implant

BACKGROUND Indication for rotating hinge (RH) total knee arthroplasty (TKA) includes primary and revision cases, with contradictory results. The aim of this study was to report prospective early results of a new modular rotating hinge TKA (EnduRo). For this implant several new design features and a new bearing material (carbon-fiber reinforced poly-ether-ether-ketone) have been developed. Furth...

متن کامل

تأثیر ویبریشن موضعی روی عضله چهار سررانی بر درمان عوارض استئوآرتریت زانو

  S. Mohammadi [1] , A.H. Bakhtiary [2] , H. Tabesh [3] , J. Moghimi [4] , R. Ghorbani [5]     Received: 09/01/2012 Sent for Revision: 09/04/2012 Received Revised Manuscript: 07/08/2012 Accepted: 08/08/2012    Background and Objectives: Recently, vibration has been used widely as a rehabilitation intervention for neuro-musculo-skeletal disorders. As, the knee osteoarthritis (OA) is a common j...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Bulletin of the Hospital for Joint Disease

دوره 72 2  شماره 

صفحات  -

تاریخ انتشار 2014