In-stent restenosis after carotid angioplasty and stenting: a challenge for the vascular surgeon.
نویسندگان
چکیده
PURPOSE This study aims to review the incidence of in-stent restenosis (ISR), the factors which determine restenosis, and to evaluate the use of various endovascular techniques for the management of ISR following carotid artery stenting (CAS). METHODS Four hundred and seven patients (334 men, mean age 63 years, range 46-86, median 65 years) were treated with CAS between December 2000 and March 2004. Three hundred and seventy-two (89%) patients had at least one ultrasound evaluation performed 6 months after procedure (range 6-40). Recurrent stenosis >80% detected with duplex ultrasound scans were further evaluated by angiography and treated with repeat endovascular procedure. RESULTS CAS was performed successfully in all cases with a Carotid WallStent (Boston Scientific) using a cerebral protection device (filter). Perioperative complications included four (0.9%) minor and two (0.4%) major strokes these latter two patients died at 5 and 12 days after the operation. No other deaths occurred. A total of 15 carotid arteries (3.6%) in 14 patients had ISR. All ISR were treated with a repeat endovascular procedure: three balloon angioplasty alone, eight angioplasty and secondary stenting, four angioplasty with cutting balloon. Postsurgical restenosis was confirmed to be the only predictive factor for the development of in-stent restenosis (OR 14.5, 95% CI 2.3-113.4, p=0.005). Endovascular treatment of ISR achieved technical success without periprocedurale complications and the absence of significant restenosis over a median follow up time of 12.4 months (range 3.5-30.7). CONCLUSION Our experience with a large cohort of CAS showed an encouragingly low incidence of ISR (3.6%) and successful treatment by repeat endovascular intervention. We recommend attempting all endovascular possibilities before performing stent removal.
منابع مشابه
Instent restenosis after carotid stenting: treatment using an off-label cardiac scoring balloon.
BACKGROUND Treatment of instent restenosis after carotid artery stenting because of circumferential or calcified lesions can be difficult and refractory to conventional balloon angioplasty. We describe the off-label use of a cardiac scoring balloon that was used for lesions refractory to angioplasty with other balloons. CASE DESCRIPTIONS Two patients with a history of carotid artery stenting ...
متن کاملRisk factors for restenosis after carotid artery angioplasty and stenting.
OBJECTIVES With carotid artery stenting (CAS) becoming an ever-increasing procedure, we sought to determine risk factors for in-stent restenosis after CAS. METHODS Consecutive patients undergoing CAS between January 2002 and October 2004 at a tertiary care hospital were retrospectively reviewed. Patient, filter, and stent selection were left to the discretion of the attending surgeon. High-ri...
متن کاملIn-stent restenosis of innominate artery with critical stenosis of right internal carotid artery.
A lady with aortitis syndrome developed in-stent restenosis (ISR) of the innominate artery stent and critical stenosis of right internal carotid artery. The therapeutic challenge was gaining access to the carotid vessel, after treating the innominate artery ISR and all the while using distal protection to circumvent potential cerebral embolism. Percutaneous transluminal angioplasty (PTA) with o...
متن کاملPhysical training increases eNOS vascular expression and activity and reduces restenosis after balloon angioplasty or arterial stenting in rats.
The effects of dynamic exercise on restenosis after vascular injury are still unknown. The consequences of balloon dilation-induced injury on neointimal hyperplasia, vascular negative remodeling, and reendothelialization were assessed in sedentary and trained rats. Ex vivo eNOS vascular expression and activity were investigated in carotid arteries isolated from sedentary and exercised rats. The...
متن کاملIncreased in-stent stenosis in ApoE knockout mice: insights from a novel mouse model of balloon angioplasty and stenting.
OBJECTIVE We aimed to develop and validate a model of angioplasty and stenting in mice that would allow investigation of the response to stent injury using genetically modified mouse strains. METHODS AND RESULTS Aortic segments from either C57BL/6 wild-type or atherosclerotic ApoE-KO mice underwent balloon angioplasty alone or balloon angioplasty and stenting with a 1.25x2.5 mm stainless stee...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery
دوره 29 6 شماره
صفحات -
تاریخ انتشار 2005