Quantification of subendocardial and subepicardial blood flow using 15O-labeled water and PET: experimental validation.

نویسندگان

  • Ornella Rimoldi
  • Klaus P Schäfers
  • Ronald Boellaard
  • Federico Turkheimer
  • Lars Stegger
  • Marilyn P Law
  • Adriaan A Lammerstma
  • Paolo G Camici
چکیده

UNLABELLED The purpose of this study was to assess the feasibility and accuracy of quantifying subendocardial and subepicardial myocardial blood flow (MBF) and the relative coronary flow reserves (CFR) using (15)O-labeled water (H(2)(15)O) and 3-dimensional-only PET. METHODS Eight pigs were scanned with H(2)(15)O and (15)O-labeled carbon monoxide (C(15)O) after partially occluding the circumflex (n = 3) or the left anterior descending (n = 5) coronary artery, both at rest and during hyperemia induced by intravenous dipyridamole. Radioactive microspheres were injected during each of the H(2)(15)O scans. RESULTS In a total of 256 paired measurements of MBF, ranging from 0.30 to 4.46 mL.g(-1).min(-1), microsphere and PET MBF were fairly well correlated. The mean difference between the 2 methods was -0.01 +/- 0.52 mL.g(-1).min(-1) with 95% of the differences lying between the limits of agreement of -1.02 and 1.01 mL.g(-1).min(-1). CFR was significantly reduced (P < 0.05) in the ischemic subendocardium (PET = 1.12 +/- 0.45; microspheres = 1.09 +/- 0.50; P = 0.86) and subepicardium (PET = 1.2 +/- 0.35; microspheres = 1.32 +/- 0.5; P = 0.39) in comparison with remote subendocardium (PET = 1.7 +/- 0.62; microspheres = 1.64 +/- 0.61; P = 0.68) and subepicardium (PET = 1.79 +/- 0.73; microspheres = 2.19 +/- 0.86; P = 0.06). CONCLUSION Dynamic measurements using H(2)(15)O and a 3-dimensional-only PET tomograph allow regional estimates of the transmural distribution of MBF over a wide flow range, although transmural flow differences were underestimated because of the partial-volume effect. PET subendocardial and subepicardial CFR were in good agreement with the microsphere values.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Feasibility of subendocardial and subepicardial myocardial perfusion measurements in healthy normals with 15O-labeled water and positron emission tomography

BACKGROUND Positron emission tomography (PET) enables robust and reproducible measurements of myocardial blood flow (MBF). However, the relatively limited resolution of PET till recently prohibited distinction between the subendocardial and the subepicardial layers in non-hypertrophied myocardium. Recent developments in hard- and software, however, have enabled to identify a transmural gradient...

متن کامل

Validation of a simplified scatter correction method for 3D brain PET with 15O

OBJECTIVE Positron emission tomography (PET) enables quantitative measurements of various biological functions. Accuracy in data acquisition and processing schemes is a prerequisite for this. The correction of scatter is especially important when a 3D PET scanner is used. The aim of this study was to validate the use of a simplified calculation-based scatter correction method for 15O studies in...

متن کامل

Tumor blood flow measured by PET dynamic imaging of first-pass 18F-FDG uptake: a comparison with 15O-labeled water-measured blood flow.

UNLABELLED PET molecular imaging of 15O-labeled water is the gold standard for measuring blood flow in humans. However, this requires an on-site cyclotron to produce the short-lived 15O tracer, which is cost-prohibitive for most clinical PET centers. The purpose of this study was to determine if the early uptake of 18F-FDG could be used to measure regional blood flow in tumors in the absence of...

متن کامل

Myocardial perfusion PET: A split function?

Positron emission tomography (PET) plays an important role in the assessment of myocardial blood flow (MBF). Absolute quantification of MBF is feasible using tracer kinetic models. The most common method for quantifying MBF involves the acquisition of dynamic images with the cyclotron-produced radiopharmaceuticals N-ammonia and O-water. An alternative method is the use of the generator produced...

متن کامل

Impact of anatomical and functional severity of coronary atherosclerotic plaques on the transmural perfusion gradient: a [15O]H2O PET study.

BACKGROUND Myocardial ischaemia occurs principally in the subendocardial layer, whereas conventional myocardial perfusion imaging provides no information on the transmural myocardial blood flow (MBF) distribution. Subendocardial perfusion measurements and quantification of the transmural perfusion gradient (TPG) could be more sensitive and specific for the detection of coronary artery disease (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 47 1  شماره 

صفحات  -

تاریخ انتشار 2006