Multi-detector row CT angiography in the assessment of carotid artery disease in symptomatic patients: comparison with rotational angiography and digital subtraction angiography.

نویسندگان

  • Marja Berg
  • Zishu Zhang
  • Aki Ikonen
  • Petri Sipola
  • Reetta Kälviäinen
  • Hannu Manninen
  • Ritva Vanninen
چکیده

BACKGROUND AND PURPOSE Compared with the single-detector technique, multi-detector row CT angiography permits larger anatomic coverage that includes both the epiaortic and entire carotid circulations. We evaluated the accuracy of multi-detector row CT angiography by using multiplanar reformation (MPR) for measuring carotid artery diameters compared with that of rotational angiography. We also evaluated the diagnostic performance of CT angiography compared with digital subtraction angiography (DSA). METHODS In 35 patients, CT angiograms of 70 carotid arteries were compared with DSA images, and CT angiograms of 33 carotid arteries were compared with rotational angiograms. CT angiographic interpretation was performed first interactively at a workstation. Diameter measurements of normal and stenosed carotid arteries were performed on cross-sectional and oblique sagittal MPRs. Degree of stenosis was calculated per North American Symptomatic Carotid Endarterectomy Trial criteria independently by two observers for each technique. RESULTS Degree of stenosis was slightly underestimated with CT angiography, with mean differences (+/- SD) per observer of 6.9 +/- 17.6% and 10.7 +/- 16.1% for cross-sectional and 2.8 +/- 19.2% and 9.1 +/- 16.8% for oblique sagittal MPRs compared with rotational angiography. CT angiography was somewhat inaccurate for measuring the absolute minimal diameter of high-grade stenoses. On symptomatic sides (n = 35), interactive CT angiographic interpretation combined with MPR measurements for lesions with a visual estimate of 50% or greater stenosis achieved a sensitivity of 95% (20/21) and specificity of 93% (13/14) in the detection of carotid stenosis (>/= 50%) verified with DSA. CONCLUSION Regardless of slight underestimation of carotid stenosis with CT angiography compared with rotational angiography, diagnostic performance of CT angiography with interactive interpretation proved to be good. Also, the method is highly sensitive for detection of carotid artery stenosis, indicating the suitability of CT angiography as a screening method for symptomatic patients. For hemodynamically significant stenoses revealed by CT angiographic screening, conventional angiography still seems to be necessary.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه یافته‌های آنژیوگرافی عروق کلیوی به روش توموگرافی کامپیوتری چندلایه با  یافته‌های جراحی در افراد زنده دهنده کلیه

Background: In kidney transplantation decision about the proper kidney donation is different between surgeons, but simple vasculature anatomy and a kidney without abnormalities are the most important reasons of choosing a kidney. Therefore    complete assessment of renal vessels of a live donor with noninvasive techniques is a necessity for nephrectomy. For delineation of the kidney vasculature...

متن کامل

ارزیابی و بررسی نتایج حاصل از داپلر فراصوتی در مقایسه با آنژیوگرافی تفریقی دیجیتال در تشخیص تنگ شدگیهای شریان کاروتید داخلی

Introduction: Digital Subtraction Angiography (DSA) is the standard method for detection of carotid artery stenosis. This technique has high radiation dose. With the progress of imaging techniques, noninvasive or minimally invasive methods like the CT angiography, MR angiography and ultrasonography with Doppler or Duplex mode were applicable. This study aimed to evaluate and assesse the results...

متن کامل

A comparison of normal intraarterial digital subtraction angiography with standard angiography in patients with symptomatic cerebrovascular ischemia.

The association between carotid artery disease, transient ischemic attack (TIA), and stroke has been recognized for many years. There still appears to be some controversy over the accuracy of lesion detection with intraarterial digital subtraction angiography (IADSA) as compared with film screen technique. We describe a prospective study that took place over a period of nearly 4 years with 30 c...

متن کامل

Internal carotid artery stenosis measurement: comparison of 3D computed rotational angiography and conventional digital subtraction angiography.

BACKGROUND AND PURPOSE Clinical trials have shown that carotid endarterectomy reduces stroke risk in symptomatic individuals with severe internal carotid artery (ICA) stenosis. As a result of these trials, digital subtraction angiography (DSA) became a standard of reference for ICA stenosis diagnosis. Newer 3D techniques provide a larger number of views than DSA, which may influence the estimat...

متن کامل

Prospective evaluation of carotid artery stenosis: elliptic centric contrast-enhanced MR angiography and spiral CT angiography compared with digital subtraction angiography.

BACKGROUND AND PURPOSE Although digital subtraction angiography (DSA) is the reference standard for assessing carotid arteries, it is uncomfortable for patients and has a small risk of disabling stroke and death. These problems have fueled the use of spiral CT angiography and MR angiography. We prospectively compared elliptic centric contrast-enhanced MR angiography and spiral CT angiography wi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 26 5  شماره 

صفحات  -

تاریخ انتشار 2005