Is the pleural fluid transudate or exudate? A revisit of the diagnostic criteria.

نویسندگان

  • J Joseph
  • P Badrinath
  • G S Basran
  • S A Sahn
چکیده

BACKGROUND Pleural effusions are classified into transudates and exudates based on criteria developed in the 1970s. However, their accuracy has not been evaluated. We compared the performance of the pleural fluid absolute lactic dehydrogenase level (FLDH), fluid to serum ratio of LDH (LDHR), and fluid to serum ratio of total protein (TPR). TPR has been used instead of the absolute value of fluid protein based on the observation that fluid protein is influenced by changes in the serum protein concentration. However, the rationale for using LDHR remains unexplored. METHODS Of 212 consecutive patients with pleural effusions, four with multiple causes and eight with an uncertain diagnosis were excluded. ROC curves were generated using sensitivity and 1-specificity values for TPR, FLDH, and LDHR and positive likelihood ratios (LR+ve) were computed using the optimum cut off values. The correlation between pleural fluid and serum concentrations of total protein and LDH was also estimated. RESULTS Of 200 effusions studied, 156 were exudates and 44 were transudates. The optimum cut off levels were: FLDH 163 IU/l, TPR 0.5, LDHR 0.6, and the FLDH-TPR combination 163 and 0.4, respectively. The area under the curve (AUC) with 95% confidence interval (CI) was: 0.89 (0.86 to 0.96) for FLDH, 0.86 (0.80 to 0.91) for TPR, 0.82 (0.77 to 0.89) for LDHR, and 0.90 (0.86 to 95) for FLDH-TPR. A significant correlation was observed between serum and pleural fluid protein levels in transudates and exudates (r=0.5 and 0.6, respectively), but the correlation between serum and pleural fluid LDH levels was insignificant. CONCLUSION FLDH is the most accurate marker for the diagnostic separation of transudates and exudates and LDHR has no role in this process. Combining TPR with FLDH appears to improve the diagnostic accuracy slightly.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnostic Value of Measurement Specific Gravity by Refractometric and Dipstick Method in Differentiation between Transudate and Exudate in Pleural and Peritoneal Fluid

Background: Accumulation of pleural and peritoneal fluid is seen in some diseases. In order to diagnose the disease and start the treatment, one of the most important actions will be to differentiate between exudates and transudates. The objective of this study was to determine the diagnostic value of measuring the specific gravity of the fluid through...

متن کامل

تعیین ارزش تشخیصی نسبت کلسترول و بیلی‌روبین مایع پلور به سرم در تعیین نوع افیوژن پلور

 The first step in diagnosing the cause of effusion is to differentiate exudate from transudate. In according to that, Light’s criteria has been used for years, but sometimes the amount of protein and LDH of the pleural effusion remains at the borderline, therefore detecting other components may be useful.   This research is a cross-sectional study with a sample of 70 patients having pleural ef...

متن کامل

Pleural fluid to serum bilirubin concentration ratio for the separation of transudates from exudates.

Whether fluid accumulating in the pleural space is a transudate or an exudate is determined by the widely used criteria of the pleural fluid to serum LDH and protein concentration ratios. Such a distinction is important for limiting the extent of the differential diagnosis of possible causes for this condition. We have found that a pleural fluid to serum total bilirubin ratio can serve the same...

متن کامل

Combined pleural fluid cholesterol and total protein in differentiation of exudates and transudates.

BACKGROUND The management strategy to be adopted in pleural effusion depends on whether an effusion is a transudate or exudate. OBJECTIVE To evaluate the usefulness of pleural fluid cholesterol and/or total protein measurements for differentiating between exudates and transudates, and to compare it with Light's criteria. METHODS In this prospective study 60 patients with pleural effusion we...

متن کامل

Diagnostic Value of Measurement Specific Gravity by Refractometric and Dipstick Method in Differentiation between Transudate and Exudate in Pleural and Peritoneal Fluid

BACKGROUND Accumulation of pleural and peritoneal fluid is seen in some diseases. In order to diagnose the disease and start the treatment, one of the most important actions will be to differentiate between exudates and transudates. The objective of this study was to determine the diagnostic value of measuring the specific gravity of the fluid through refractometer and strip in differentiation ...

متن کامل

Pleural Fluid Analysis: Standstill or a Work in Progress?

Pleural fluid analysis yields important diagnostic information in pleural effusions in combination with clinical history, examination, and radiology. For more than 30 years, the initial and most pragmatic step in this process is to determine whether the fluid is a transudate or an exudate. Light's criteria remain the most robust in separating the transudate-exudate classification which dictates...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Thorax

دوره 56 11  شماره 

صفحات  -

تاریخ انتشار 2001