Lag correction model and ghosting analysis for an indirect‐conversion flat‐panel imager

نویسندگان

  • Noor Mail
  • Peter O'Brien
  • Geordi Pang
چکیده

Cone-beam digital tomosynthesis (CBDT) is a new approach that was recently proposed for rapid tomographic imaging of soft-tissue targets in the radiotherapy treatment room. One of the potential problems in implementing CBDT using, for example, megavoltage (MV) X rays is the possibility of artifacts caused by image lag and ghosting of the X-ray detector used. In the present work, we developed a model to correct for image lag with indirect-conversion flat-panel imagers (FPIs) used for MV-CBDT. This model is based on measurement and analysis of image lag in an indirect-conversion FPI irradiated with a 6-MV X-ray beam. Our results demonstrated that image lag is amenable to correction. In addition, we measured the ghosting effect for an indirect-conversion FPI and found it to be insignificant.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vivo dose verification using using an amorphous silicon flat panel-type imager (a-Si EPIDs)

Introduction: Electronic portal imaging devices (EPIDs) could be used to dose verification of radiotherapy treatment plans. In vivo dose verification is performed to reduce differences found between dose delivered to the patient and the prescribed dose. The aim of this study was to perform a fast and efficient technique for the verification of delivered dose to the patient usin...

متن کامل

A ghost story: spatio-temporal response characteristics of an indirect-detection flat-panel imager.

Spatial and temporal imaging characteristics of an amorphous silicon flat-panel imager (FPI) were investigated in terms relevant to the application of such devices in cone-beam computed tomography (CBCT) and other x-ray imaging modalities, including general radiography, fluoroscopy, mammography, radiotherapy portal imaging, and nondestructive testing. Specifically, issues of image lag (includin...

متن کامل

An empirical method for lag correction in cone-beam CT.

Image lag degrades image quality in cone-beam CT (CBCT), resulting in contrast reduction, lack of CT number accuracy and uniformity, and skin-line artifacts. The magnitude of such degradation and the extent to which imaging performance can be improved by means of a lag correction method were investigated. Measurements were performed using a radiotherapy CBCT guidance system (Elekta Synergy XVI,...

متن کامل

Amorphous Silicon Flat Panel Imagers for Medical Application

A new gamma camera based on hydrogenated amorphous silicon (a-Si:H) pixel arrays to be used in nuclear medicine is introduced. Various performance characteristics of a-Si:H imagers are reviewed and compared with those of currently used equipment. An important component in the a-Si:H imager is the scintillator screen. A new approach for fabrication of high resolution CsI(Tl) scintillator layers,...

متن کامل

AbstractID: 14240 Title: Efficacy of a linear lag correction algorithm in an a-Si flat-panel x-ray detector

ID: 14240 Title: Efficacy of a linear lag correction algorithm in an a-Si flat-panel x-ray detector Purpose: Lag in a-Si flat-panel detectors (FPD) causes significant artifact. To date, most correction models have assumed a linear, time-invariant model (LTIM). We investigated detector response as a function of incident exposure. Method and Materials: The physics theory for charge trapping in FP...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2007