Iatrogenic catheter sheath shearing during radial artery cannulation

نویسندگان

  • Il-Seok Kim
  • Ho Kyun Shin
  • Dae Yu Kim
چکیده

Corresponding author: Il-Seok Kim, M.D., Department of Anesthesiology and Pain Medicine, Kangdong Sacred Heart Hospital, Hallym University College of Medicine, 445, Gil-dong, Gangdong-gu, Seoul 134-010, Korea. Tel: 82-2-2224-2659, Fax: 82-2-474-0956, E-mail: [email protected] This is an open-access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of radial artery catheter placement by respiratory therapists using ultrasound guidance.

BACKGROUND The use of ultrasound (US) guidance for radial artery cannulation has been shown to improve first attempt success rate, reduce time to successful cannulation, and reduce complications. We sought to determine whether properly trained respiratory therapists (RTs) could utilize US guidance for the placement of radial artery catheters. Primary outcome measurements were successful cannula...

متن کامل

Unusual complication of radial artery cannulation.

Currently, radial artery cannulation is the preferred method for continuous hemodynamic monitoring in critically ill patients. Reported complications of radial artery cannulation include infection, digital gangrene, thrombosis, pseudoaneurysm, skin necrosis and median nerve palsy. Radial artery catheter fracture is a very rare complication. A review of the English language literature revealed o...

متن کامل

Management of an iatrogenic radial artery perforation: a case report.

A 73-year-old female patient underwent transradial coronary angiography with stable angina and signs of significant myocardial ischemia revealed by exercise stress test. After insertion of a 6F radial sheath into the right radial artery and intra-arterial administration of heparin plus verapamil, the hydrophilic guidewire could not be advanced under fluoroscopic guidance. Immediately afterwards...

متن کامل

Use Of A Unique Long Pre-curved Sheath To Facilitate Femoral Placement Of Coronary Sinus Catheters

METHODS Catheterization of the coronary sinus (CS) from the femoral vein is widely used during electrophysiologic procedures. Access to the CS may be difficult. To address this problem we explored the utility of a long pre-formed (SAFL) sheath in a cohort of consecutive patients requiring CS cannulation in the electrophysiology laboratory. This unique sheath has distal curvatures in 2 planes, p...

متن کامل

Idiopathic radial artery aneurysm in the anatomical snuff box.

An otherwise fit and well 40-year-old left-handed male computer operator presented with a minimally symptomatic lump of 2 years duration in his non-dominant anatomical snuffbox. There was no history of trauma. This was pulsatile and did not transilluminate despite being referred as a ganglion. MRI scan confirmed the presence of a 1.5 cm radial artery aneurysm fed by the radial artery and draini...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 65  شماره 

صفحات  -

تاریخ انتشار 2013