Development and Validation of a Stability-Indicating RP-UPLC Method for the Estimation of Impurities in Cinacalcet Hydrochloride API and its Formulation.

نویسندگان

  • Pingili Sunil Reddy
  • Thummala Veera Raghava Raju
  • Penmetsa Satyanarayana Raju
  • Nadimpalli Sunil Varma
  • Kondra Sudhakar Babu
چکیده

A sensitive, stability-indicating, gradient reversed-phase ultra-performance liquid chromatography method has been developed for the quantitative estimation of cinacalcet hydrochloride impurities in active pharmaceutical ingredients and pharmaceutical formulations. Efficient chromatographic separation was achieved on an Acquity BEH Shield RP18, 100 × 2.1 mm, 1.7 µm column with the mobile phase containing pH 6.6 phosphate buffer and acetonitrile. The flow rate of the mobile phase was 0.3 mL min(-1) with a column temperature of 35°C and detection wavelength at 223 nm. The relative response factor values of (+)-R-1-(1-Naphthyl)ethylamine, regioisomer, diastereomer isomer-1, and diastereomer isomer-2 were 1.79, 0.99, 0.89, and 0.88, respectively. The cinacalcet hydrochloride formulation sample was subjected to the stress conditions of acid, base, oxidative, hydrolytic, thermal, humidity, and photolytic degradation. Cinacalcet hydrochloride was found to degrade significantly under the peroxide stress conditions. The degradation products were well-resolved from cinacalcet hydrochloride and its impurities. The peak purity test results confirmed that the cinacalcet hydrochloride peak was homogenous in all stress samples and the mass balance was found to be more than 96%, thus proving the stability-indicating power of the method. The developed method was validated according to ICH guidelines.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms

A New Stability Indicating RP-HPLC Method Development and Validation for the Simultaneous Estimation of Dolutegravir and Rilpivirine in Bulk and its Dosage Forms. Abstract The objective of the work is to develop and validate a new, simple, highly sensitive, stability indicating RP-HPLC method for simultaneous estimation of Dolutegravir and Rilpivirine in bulk and its dosage f...

متن کامل

Development and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.

AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm  4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...

متن کامل

Development and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.

AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm  4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...

متن کامل

A stability-Indicating HPLC Method for Simultaneous Determination of Creatine Phosphate Sodium and its Related Substances in Pharmaceutical Formulation

The objective of the study was to develop a simple, specific and stability-indicating HPLC method for the simultaneous determination of creatine phosphate sodium (CPS) and its related substances in pharmaceutical formulation. Separation of creatine phosphate sodium from its major process impurities and degradation products was achieved on a Hypersil BDS C18 column (250 × 4.6 mm, 5 μm) with an a...

متن کامل

A Rapid, Stability Indicating RP-UPLC Method for Simultaneous Determination of Ambroxol Hydrochloride, Cetirizine Hydrochloride and Antimicrobial Preservatives in Liquid Pharmaceutical Formulation

A stability indicating reversed phase ultra performance liquid chromatography (RP-UPLC) method was developed for simultaneous determination of ambroxol hydrochloride (AMB), cetirizine hydrochloride (CTZ), methylparaben (MP) and propylparaben (PP) in liquid pharmaceutical formulation. The desired chromatographic separation was achieved on an Agilent Eclipse plus C18, 1.8 μm (50 × 2.1 mm) column ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Scientia pharmaceutica

دوره 83 4  شماره 

صفحات  -

تاریخ انتشار 2015