Atrial lead placement at the lower atrial septum: a potential strategy to reduce unnecessary right ventricular pacing.
نویسندگان
چکیده
AIMS Right ventricular (RV) pacing has been shown to be potentially detrimental to left ventricular function. In conventional dual-chamber pacing the position of the atrial lead could influence duration of the atrio-ventricular (AV) intervals, which is one of the variables that could be associated with an increased percentage of RV pacing. We wanted to see if lead placement at selected atrial septal sites could reduce AV intervals in patients receiving a dual-chamber pacemaker or implantable cardioverter defibrillator. METHODS AND RESULTS This was a prospective, acute, randomized single centre study that enrolled 57 patients. The atrial lead was placed in both the right atrial appendage (RAA) and the lower atrial septum (LAS) in each patient in random order. The P-wave durations, PR intervals, A sense-V sense (As-Vs), and A pace-V sense (Ap-Vs) intervals were measured at both atrial lead locations in each patient during device implant. The P-wave durations during sinus rhythm (SR), RAA pacing, and LAS pacing were 113 ± 19, 144 ± 27, and 84 ± 12 ms (RAA vs. LAS, P < 0.001), respectively. The PR intervals during SR, RAA pacing, and LAS pacing were 195 ± 47, 230 ± 61, and 167 ± 44 ms (RAA vs. LAS, P < 0.001), respectively. The As-Vs interval was 31% shorter in LAS pacing than in RAA pacing (134 ± 44 ms vs. 194 ± 52 ms, P < 0.001). The Ap-Vs interval was 24% shorter during LAS pacing than during RAA pacing (195 ± 45 ms vs. 257 ± 63 ms, P < 0.001). CONCLUSION When compared with RAA pacing, LAS pacing was associated with a shorter P wave duration, PR interval, As-Vs, and Ap-Vs intervals. The potential long-term impact of the strategy of pacing from LAS in reducing unnecessary RV pacing needs to be explored in future studies.
منابع مشابه
Selective site pacing: defining and reaching the selected site.
Selective site right ventricular pacing has been suggested as an approach to reduce the incidence of ventricular dysfunction and hopefully influence the morbidity resulting from traditional right ventricular apical pacing. Pacing from the right ventricular apex allows a stable ventricular rate, and together with atrial pacing and sensing, helps maintain atrioventricular synchrony but does not a...
متن کاملLong-term epicardial ventricular pacing from endocardial bipolar pacemaker lead: perforation of right atrial wall.
One of the hazards of endocardial cardiac pacing is that the pacemaker lead may perforate the myocardial wall or interventricular septum although the incidence of such perforations is believed to be small. This paper describes what is believed to be a unique case in which a pacemaker lead perforated the atrial wall at implantation (or possibly shortly afterwards) and yet gave satisfactory right...
متن کاملSeptal Pacing of Right Ventricle: Has The Last Word Been Said?
The deleterious effects of Right ventricular (RV) pacing on development of ventricular dyssynchrony leading to heart failure, genesis of atrial fibrillation and consequent increased mortality have been repeatedly demonstrated in numerous pacing studies. Trials with dual chamber pacemakers and defibrillators did not succeed in negating these effects, raising the question if it was RV pacing per ...
متن کاملNew manifestations of electrophysiological remodeling of heart during experimental model of atrial fibrillation in cirrhotic rat isolated heart
Introduction: The present study is aimed to evaluate electrophysiological remodeling of atrioventricular (AV) node and ventricular conduction during experimental atrial fibrillation (AF) model in isolated heart of cirrhotic rats. Methods: Cirrhosis-induced electrophysiological remodeling was evaluated in 24 isolated retrogradely perfused rat hearts in 2 groups (control and cirrhotic). Cirrho...
متن کاملFeasibility and Acute Hemodynamic Effect of Left Ventricular Septal Pacing by Transvenous Approach Through the Interventricular Septum.
BACKGROUND Left ventricular septal (LVS) pacing reduces ventricular dyssynchrony and improves cardiac function relative to right ventricular apex (RVA) pacing in animals. We aimed to establish permanent placement of an LVS pacing lead in patients using a transvenous approach through the interventricular septum. METHODS AND RESULTS Ten patients with sinus node dysfunction scheduled for dual-ch...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology
دوره 14 9 شماره
صفحات -
تاریخ انتشار 2012