Segmentation of artifacts and anatomy in CT metal artifact reduction.

نویسندگان

  • Seemeen Karimi
  • Pamela Cosman
  • Christoph Wald
  • Harry Martz
چکیده

PURPOSE Metal objects present in x-ray computed tomography (CT) scans are accompanied by physical phenomena that render CT projections inconsistent with the linear assumption made for analytical reconstruction. The inconsistencies create artifacts in reconstructed images. Metal artifact reduction algorithms replace the inconsistent projection data passing through metals with estimates of the true underlying projection data, but when the data estimates are inaccurate, secondary artifacts are generated. The secondary artifacts may be as unacceptable as the original metal artifacts; therefore, better projection data estimation is critical. This research uses computer vision techniques to create better estimates of the underlying projection data using observations about the appearance and nature of metal artifacts. METHODS The authors developed a method of estimating underlying projection data through the use of an intermediate image, called the prior image. This method generates the prior image by segmenting regions of the originally reconstructed image, and discriminating between regions that are likely to be metal artifacts and those that are likely to represent anatomical structures. Regions identified as metal artifact are replaced with a constant soft-tissue value, while structures such as bone or air pockets are preserved. This prior image is reprojected (forward projected), and the reprojections guide the estimation of the underlying projection data using previously published interpolation techniques. The algorithm is tested on head CT test cases containing metal implants and compared against existing methods. RESULTS Using the new method of prior image generation on test images, metal artifacts were eliminated or reduced and fewer secondary artifacts were present than with previous methods. The results apply even in the case of multiple metal objects, which is a challenging problem. The authors did not observe secondary artifacts that were comparable to or worse than the original metal artifacts, as sometimes occurred with the other methods. The accuracy of the prior was found to be more critical than the particular interpolation method. CONCLUSIONS Metals produce predictable artifacts in CT images of the head. Using the new method, metal artifacts can be discriminated from anatomy, and the discrimination can be used to reduce metal artifacts.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Metal Artifact Reduction of Dental Fillings in Head and Neck CT Images

Introduction: The issue of metal artifact and its reduction is as old as the clinical use of computed tomography itself. When metal objects such as dental fillings, hip prostheses or surgical clips are present in the computed tomography (CT) field of view (FOV), make severe artifacts that reduce the image quality and accuracy of CT numbers. They can lead to unreliable ...

متن کامل

Evaluation of Metal Artifact Reduction software in Computed Tomography

Introduction: The image quality of computed tomography (CT) can be seriously lowered by metal implants of patients. These implants are known to exert a significant impact on diagnostic accuracy due to artifacts. The current study aimed to assess the usefulness of Metal Artifact Reduction (MAR) software in the reduction of metal artifacts, in comparison to iterative rec...

متن کامل

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Is correction for metallic artefacts mandatory in cardiac SPECT/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Introduction: Metallic artifacts due to pacemaker/ implantable cardioverter defibrillator (ICD) leads in CT images can produce artifactual uptake in cardiac SPECT/CT images. The aim of this study was to determine the influence of the metallic artifacts due to pacemaker and ICD leads on myocardial SPECT/CT imaging. Methods: The study included 9 patients wh...

متن کامل

A New Method for Metal Artifact Reduction in CT Scan Images

Introduction In CT imaging, metallic implants inside the tissues cause metal artifact that reduce the quality of image for diagnosis. In order to reduce the effect of this artifact, a new method with more appropriate results has been presented in this research work. Materials and Methods The presented method comprised of following steps: a) image enhancement and metal areas extraction, b) sinog...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 39 10  شماره 

صفحات  -

تاریخ انتشار 2012