Intubation performance using different laryngoscopes while wearing chemical protective equipment: a manikin study
نویسندگان
چکیده
OBJECTIVES This study aimed to compare visualisation of the vocal cords and performance of intubation by anaesthetists using four different laryngoscopes while wearing full chemical protective equipment. SETTING Medical simulation center of a university hospital, department of anaesthesiology. PARTICIPANTS 42 anaesthetists (15 females and 27 males) completed the trial. The participants were grouped according to their professional education as anaesthesiology residents with experience of <2 years or <5 years, or as anaesthesiology specialists with experience of >5 years. INTERVENTIONS In a manikin scenario, participants performed endotracheal intubations with four different direct and indirect laryngoscopes (Macintosh (MAC), Airtraq (ATQ), Glidescope (GLS) and AP Advance (APA)), while wearing chemical protective gear, including a body suit, rubber gloves, a fire helmet and breathing apparatus. PRIMARY AND SECONDARY OUTCOME MEASURES With respect to the manikin, setting time to complete 'endotracheal intubation' was defined as primary end point. Glottis visualisation (according to the Cormack-Lehane score (CLS) and impairments caused by the protective equipment, were defined as secondary outcome measures. RESULTS The times to tracheal intubation were calculated using the MAC (31.4 s; 95% CI 26.6 to 36.8), ATQ (37.1 s; 95% CI 28.3 to 45.9), GLS (35.4 s; 95% CI 28.7 to 42.1) and APA (23.6 s; 95% CI 19.1 to 28.1), respectively. Intubation with the APA was significantly faster than with all the other devices examined among the total study population (p<0.05). A significant improvement in visualisation of the vocal cords was reported for the APA compared with the GLS. CONCLUSIONS Despite the restrictions caused by the equipment, the anaesthetists intubated the manikin successfully within adequate time. The APA outperformed the other devices in the time to intubation, and it has been evaluated as an easily manageable device for anaesthetists with varying degrees of experience (low to high), providing good visualisation in scenarios that require the use of chemical protective equipment.
منابع مشابه
A randomised crossover trial comparing the Airtraq(®) NT, McGrath(®) MAC and Macintosh laryngoscopes for nasotracheal intubation of simulated easy and difficult airways in a manikin.
OBJECTIVE Several devices can aid nasotracheal intubation when managing difficult airways. The McGrath MAC and Airtraq NT were compared with a Macintosh laryngoscope when studying the performance of anaesthetists with different levels of experience, in a manikin model of easy or difficult airway scenarios. METHODS Sixty-three anaesthetists were recruited into a randomised trial in which each ...
متن کاملComparison of Indirect Video Laryngoscopes in Children Younger than Two Years of Age: a Randomized Trainee Evaluation Study.
BACKGROUND Gaining proficiency with various airway management tools is an important goal for anesthesiology training. Indirect video laryngoscopes facilitate tracheal intubation in adults, but it is not clear whether these findings translate to children. This study evaluates the total time to successful intubation when performed by anesthesiology trainees using GlideScope Cobalt® video laryngos...
متن کاملComparison of Miller and Airtraq laryngoscopes for orotracheal intubation by physicians wearing CBRN protective equipment during infant resuscitation: a randomized crossover simulation study.
BACKGROUND The purpose of this study was to evaluate the performance of orotracheal intubation with the Miller laryngoscope compared with the Airtraq laryngoscope by emergency and pediatric physicians wearing CBRN-PPE type III on infant manikins with conventional airway. We hypothesized that in this situation, the orotracheal intubation with the Airtraq laryngoscope would be faster and more eff...
متن کاملChemical protective clothing; a study into the ability of staff to perform lifesaving procedures.
OBJECTIVE To investigate the ability of medical and nursing staff to perform certain tasks while wearing a chemical protection suit with a respirator. Tasks chosen were those that would be required before decontamination. METHODS Ten experienced accident and emergency doctors (middle grade and consultants) and 10 nurses were asked to perform certain tasks that were judged to be life saving, r...
متن کاملChemical protective clothing; a study into the ability of staV to perform lifesaving procedures
Objective—To investigate the ability of medical and nursing staV to perform certain tasks while wearing a chemical protection suit with a respirator. Tasks chosen were those that would be required before decontamination. Methods—Ten experienced accident and emergency doctors (middle grade and consultants) and 10 nurses were asked to perform certain tasks that were judged to be life saving, rele...
متن کامل