The forced oscillation technique in clinical practice: methodology, recommendations and future developments.

نویسندگان

  • E Oostveen
  • D MacLeod
  • H Lorino
  • R Farré
  • Z Hantos
  • K Desager
  • F Marchal
چکیده

The forced oscillation technique (FOT) is a noninvasive method with which to measure respiratory mechanics. FOT employs small-amplitude pressure oscillations superimposed on the normal breathing and therefore has the advantage over conventional lung function techniques that it does not require the performance of respiratory manoeuvres. The present European Respiratory Society Task Force Report describes the basic principle of the technique and gives guidelines for the application and interpretation of FOT as a routine lung function test in the clinical setting, for both adult and paediatric populations. FOT data, especially those measured at the lower frequencies, are sensitive to airway obstruction, but do not discriminate between obstructive and restrictive lung disorders. There is no consensus regarding the sensitivity of FOT for bronchodilation testing in adults. Values of respiratory resistance have proved sensitive to bronchodilation in children, although the reported cutoff levels remain to be confirmed in future studies. Forced oscillation technique is a reliable method in the assessment of bronchial hyperresponsiveness in adults and children. Moreover, in contrast with spirometry where a deep inspiration is needed, forced oscillation technique does not modify the airway smooth muscle tone. Forced oscillation technique has been shown to be as sensitive as spirometry in detecting impairments of lung function due to smoking or exposure to occupational hazards. Together with the minimal requirement for the subject's cooperation, this makes forced oscillation technique an ideal lung function test for epidemiological and field studies. Novel applications of forced oscillation technique in the clinical setting include the monitoring of respiratory mechanics during mechanical ventilation and sleep.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ERS TASK FORCE The forced oscillation technique in clinical practice: methodology, recommendations and future developments

The forced oscillation technique in clinical practice: methodology, recommendations and future developments. E. Oostveen, D. MacLeod, H. Lorino, R. Farré, Z. Hantos, K. Desager, F. Marchal, on behalf of the ERS Task Force on Respiratory Impedance Measurements. #ERS Journals Ltd 2003. ABSTRACT: The forced oscillation technique (FOT) is a noninvasive method with which to measure respiratory mecha...

متن کامل

Is forced oscillation technique the next respiratory function test of choice in childhood asthma

Respiratory diseases, especially asthma, are common in children. While spirometry contributes to asthma diagnosis and management in older children, it has a limited role in younger children whom are often unable to perform forced expiratory manoeuvre. The development of novel diagnostic methods which require minimal effort, such as forced oscillation technique (FOT) is, therefore, a welcome and...

متن کامل

Within-Breath Analysis of Respiratory Mechanics in Asthmatic Patients by Forced Oscillation

INTRODUCTION The within-breath analysis of respiratory mechanics by the monofrequency Forced Oscillation Technique (mFOT) is of great interest in both physiopathology studies and the diagnosis of respiratory diseases. However, there are limited data on the use of this technique in the analysis of asthma. This study evaluates within-breath mechanics of asthmatic individuals and the contribution ...

متن کامل

Clinical guideline of neurosurgical practice during the COVID-19 pandemic

Background: Neurosurgery practice conflicts with many challenges during the COVID-19 pandemic; Including the lack of beds in intensive care units, as well as the use of some methods such as drills and trans-nasal and trans-oral approaches that produce aerosols or are directly in contact with patient discharge. Due to these challenges, developing a clinical guideline to help neurosurgeons and me...

متن کامل

Servocontrolled generator to measure respiratory impedance from 0.25 to 26 Hz in ventilated patients at different PEEP levels.

Assessing respiratory impedance (Zrs) in ventilated patients over a wide frequency band, ranging from breathing rates to typical forced oscillation frequencies, during end-expiratory pauses at different positive end-expiratory pressures (PEEP) is of potential interest to assess a patient's respiratory mechanics. Zrs measurements under these conditions are not possible with the present variants ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 22 6  شماره 

صفحات  -

تاریخ انتشار 2003