SNR and B1 Homogeneity Analysis of Intra-Vascular/Cavity RF Coil Designs
نویسندگان
چکیده
S. B. King, J. Bellec, V. Volotovskyy, H-Y. Lin, C. P. Bidinosti, K. Jasinski, M. J. Smith, and B. Tomanek Institute for Biodiagnostics, National Research Council of Canada, Winnipeg, Manitoba, Canada, Department of Physics, University of Winnipeg, Winnipeg, Manitoba, Canada, Department of Magnetic Resonance Imaging, Polish Academy of Sciences, H. Niewodniczanski Institute of Nuclear Physics, Krakow, Poland, Institute for Biodiagnostics (West), National Research Council of Canada, Calgary, Alberta, Canada
منابع مشابه
Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences
Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of non-homogeneity in RF receive and transmit. This can be the most effective source of error in quantitative studies in MRI imaging. Part of this non-homogeneity demonstrates the characteristics of RF coil and part of it is due to the interaction of RF field with the material being imaged...
متن کاملComparison of B1 Field Homogeneity for Shielded Birdcage, TEM and Microstrip Volume Coils at 300MHz
Introduction: Because of the inherent advantage of improved SNR, ultra-high field (3T~9.4T) MRI technology and applications have been accelerated these years. However many engineering challenges have arisen from high-operation frequencies. One major challenge is the difficulty of designing large-size RF coils with high-resonance frequencies. In addition, it has been shown that the homogeneity o...
متن کاملA birdcage coil tuned by RF shielding for application at 9.4 T.
The design and performance of an inductively fed low-pass birdcage radiofrequency (RF) coil for applications at 9.4 T are described where tuning is accomplished by mechanically moving a concentric RF shield about the longitudinal axis of an RF coil. Moving the shield about the RF coil effectively changes the mutual inductance of the system, providing a mechanism for adjusting the resonant frequ...
متن کاملB 1 shimming with a standard 2 channel headcoil at 7 T : possibilities & limitations
Purpose: To study the possibilities and limitations of RF phase and amplitude shimming with a standard 2 channel head coil at 7T. Introduction One of the main problems in high field MRI is the reduced SNR and loss in contrast due to inhomogeneous B1 RF transmit fields. Spatial homogeneity is of primary importance for diagnostic imaging. At 3T the homogeneity problem is mainly limited to regions...
متن کاملTraveling Wave Imaging of the Human Head at 7 Tesla: Assessment of SNR, Homogeneity and B1+ Efficiency
Introduction: The traveling wave concept for 7T MR imaging was first demonstrated by Brunner et al [1]. In the most common RF transmit coil designs, a quadrature RF field is created within a cylindrical volume in the near-field regime. In contrast, the traveling wave approach creates a traveling wave mode down the entire bore of the scanner. This has the potential to provide more uniform excita...