Temporal artery thermometry in children younger than 5 years: a comparison with rectal thermometry.

نویسندگان

  • Kelechi K Odinaka
  • Benedict O Edelu
  • Charles E Nwolisa
  • Ifeyinwa B Amamilo
  • Seline N Okolo
چکیده

BACKGROUND Temporal artery (TA) thermometry has come as one of the new methods for temperature measurement, especially in children in whom accurate temperature monitoring can save lives. The device which is convenient and simple to use is yet to gain popularity in several parts of the world, as there are conflicting reports of its accuracy. This study compares the accuracy of the TA thermometry in children younger than 5 years using the rectal thermometry as the gold standard. METHODS Temperature was measured simultaneously in eligible children younger than 5 years from the forehead and rectum using the TA thermometer (TAT-2000C Exergen, USA) and standard mercury in glass rectal thermometer, respectively. The difference between the mean temperatures obtained by the 2 thermometry methods was tested using the paired t test. Pearson correlation coefficient, linear regression, and Bland-Altman plot were also used to test the relationship and agreement between the 2 instruments. The sensitivity, specificity, and positive and negative predictive values were also calculated. RESULTS Overall, the mean TA temperature (37.80°C ± 1.07°C) was significantly lower than the mean rectal temperature (38.07°C ± 0.95°C), P < 0.001. In neonates, however, the mean difference was not significant, 0.02 ± 0.59 (P = 0.810). There was a significant positive correlation between the rectal and the temporal temperatures (r = 0.80, P < 0.01). The Bland-Altman plot showed wide variation in the limit of agreement between the rectal and the TA temperatures which ranged from -1.02°C to +1.56°C. The sensitivity of the TA thermometer was 64.6% and 83.5%, respectively, at a TA fever cutoff of 38.0°C and 37.7°C. CONCLUSIONS Temporal artery thermometer is not accurate enough for the measurement of core body temperature in children younger than 5 years. However, it may be used as a tool for screening for fever in very busy clinics and emergency room at a fever cutoff of 37.7°C.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acceptance of temporal artery thermometry by Nigerian mothers: a comparison with the traditional methods

INTRODUCTION Temporal artery thermometry may be viewed as a suitable alternative to the traditional thermometry because of its safety and time efficiency. However, it is yet to gain wide acceptance in African settings because it is relatively new. The aim of this study was to compare the choices of Nigerian mothers between the traditional methods (axillary and rectal thermometry) and the tempor...

متن کامل

Accuracy of a noninvasive temporal artery thermometer for use in infants.

OBJECTIVES To assess the accuracy of a new noninvasive temporal artery (TA) thermometer in infants; to compare the accuracy of the TA thermometer with that of a tympanic thermometer, using rectal thermometry as the criterion standard; and to compare the tolerability of the TA thermometer with that of the tympanic and rectal thermometers. DESIGN Prospective evaluation of the accuracy of TA and...

متن کامل

Diagnostic accuracy of three different methods of temperature measurement in acutely ill geriatric patients.

OBJECTIVE we examined the diagnostic accuracy of different methods of body temperature measurement to diagnose infection in geriatric patients presenting to the emergency department (ED). METHODS this observational study was done in consecutive patients ≥75 years old presenting to the ED. Body temperature was determined by tympanal thermometry, temporal artery thermometry and rectal temperatu...

متن کامل

Non-Invasive Temporal Artery Thermometry: Physics, Physiology, and Clinical Accuracy

Temporal artery (TA) thermometry was developed in answer to requests by pediatricians for a replacement for: 1) ear thermometry due to inaccuracy; and 2) rectal thermometry due to parents’ (and most clinicians’) growing dislike of the method. The underlying technology development spans some 20 years, borrowing heavily from methods invented for industrial processes and medical research. Although...

متن کامل

Detecting fever in young infants: reliability of perceived, pacifier, and temporal artery temperatures in infants younger than 3 months of age.

OBJECTIVES Fever in young infants frequently triggers a laboratory evaluation because of the increased likelihood of serious bacterial infections. Reported fever by methods other than rectal thermometry is of concern. This study evaluates the validity of perceived, pacifier, and temporal artery (TA) temperatures. METHODS A convenience sample of 200 babies younger than 3 months of age presenti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Pediatric emergency care

دوره 30 12  شماره 

صفحات  -

تاریخ انتشار 2014