Evaluation of left atrial volume and function using single beat real time 3-demensional echocardiography in atrial fibrillation patients
نویسندگان
چکیده
Title: Evaluation of left atrial volume and function using single-beat real-time three-dimensional echocardiography in atrial fibrillation patients Authors: Qian Zhang ([email protected]) Ju-fang Wang ([email protected]) Qing-qing Dong ([email protected]) Qing Yan ([email protected]) Xiang-hong Luo ([email protected]) Xue-ying Wu ([email protected]) Jian Liu ([email protected]) Ya-ping Sun ([email protected]) Version: 1 Date: 31 May 2017 Author’s response to reviews: BMIM-D-16-00187 Evaluation of left atrial volume and function using single beat real time 3-demensional echocardiography in atrial fibrillation patients Qian Zhang; Ju-fang Wang; Qing-qing Dong; Qing Yan; Xiang-hong Luo; Xue-ying Wu; Jian Liu; Ya-ping Sun
منابع مشابه
Evaluation of left atrial volume and function using single-beat real-time three-dimensional echocardiography in atrial fibrillation patients
BACKGROUND This study was aimed to evaluate the feasibility and accuracy of real-time three-dimensional echocardiography (RT-3DE) measurement of left atrial (LA) volume and function in comparison with two-dimensional echocardiography (2DE) measurements in atrial fibrillation (AF) patients. METHODS A total of 50 pairs of AF patients and healthy controls were enrolled in this study. Indexed LA ...
متن کاملThree-dimensional echocardiography using single-heartbeat modality decreases variability in measuring left ventricular volumes and function in comparison to four-beat technique in atrial fibrillation
BACKGROUND Three dimensional echocardiography (3DE) approaches the accuracy of cardiac magnetic resonance in measuring left ventricular (LV) volumes and ejection fraction (EF). The multibeat modality in comparison to single-beat (SB) requires breath-hold technique and regular heart rhythm which could limit the use of this technique in patients with atrial fibrillation (AF) due to stitching arti...
متن کاملElectro-Anatomic (CARTO) Mapping for Measurement of Left Atrial Volume: Validation Against Real-Time 3D Echocardiography
Background: Left atrial size is a determinant of atrial fibrillation ablation efficacy and embolic risk. The recent advent of real-time full-volume 3DE allows now rapid measurement of chamber volume more accurately than with standard two-dimensional echocardiography as volume is reconstructed from endocardial contours of the entire chamber without making geometric assumptions. Electro-anatomic ...
متن کاملAutomated quantification of left atrial size using three-beat averaging real-time three dimensional Echocardiography in patients with atrial fibrillation
BACKGROUND Left atrial (LA) sizing in patients with atrial fibrillation (AF) is crucial for follow-up and outcome. Recently, the automated quantification of LA using the novel three-beat averaging real-time three dimensional echocardiography (3BA-RT3DE) is introduced. The aim of this study was to assess the feasibility and accuracy of 3BA-RT3DE in patients with atrial fibrillation (AF). METHO...
متن کاملClinical Significance of P Wave Dispersion in Prediction of Atrial Fibrillation in Patients with Acute Myocardial Infarction
Background: P wave dispersion (PWD) is defined as the difference between the maximum P wave duration (Pmax) and the minimum P wave duration (Pmin) in 12-leads of the surface electrocardiography. The aim of this study was to evaluate the values of PWD during atrial fibrillation (AF) after acute myocardial infarction (AMI). Methods: We prospectively evaluated atrial rhythms of 350 patients (251 m...
متن کامل