Echo-planar imaging of intravoxel incoherent motion.

نویسندگان

  • R Turner
  • D Le Bihan
  • J Maier
  • R Vavrek
  • L K Hedges
  • J Pekar
چکیده

The recently established single-shot technique of echo-planar imaging of intravoxel incoherent motion (IVIM) for determining and imaging the variations of microscopic motions of water has been applied to studies of water perfusion in phantoms and to in vivo studies of diffusion and perfusion in cat and human brains. The phantom results demonstrate that perfusion levels comparable with those found in vivo have easily observable and reproducible effects on signal amplitude that are consistent with previous IVIM theory. Reliable measurements of the diffusion coefficient in various types of brain tissue have been obtained. The results for white matter are consistent with the existence of anisotropic diffusion in oriented bundles of myelinated nerve fibers. The results for gray matter can be fitted to the IVIM theory and suggest a value of up to 14% for the fraction of the signal contributed by randomly perfusing fluid in normal cerebral cortex.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vivo intravoxel incoherent motion measurements in the human placenta using echo-planar imaging at 0.5 T.

This paper presents the first in vivo measurements of intravoxel incoherent motion in the human placenta, obtained using the pulsed gradient spin echo (PGSE) sequence. The aims of this study were two-fold. The first was to provide an initial estimate of the values of the IVIM parameters in this organ, which are currently unknown. The second aim was then to use these results to optimize the sequ...

متن کامل

Functional Mapping of the Human Visual Cortex with Intravoxel Incoherent Motion MRI

Functional imaging with intravoxel incoherent motion (IVIM) magnetic resonance imaging (MRI) is demonstrated. Images were acquired at 3 Tesla using a standard Stejskal-Tanner diffusion-weighted echo-planar imaging sequence with multiple b-values. Cerebro-spinal fluid signal, which is highly incoherent, was suppressed with an inversion recovery preparation pulse. IVIM microvascular perfusion par...

متن کامل

Non-parametric intravoxel incoherent motion analysis of the thyroid gland

PURPOSE To implement a protocol for intravoxel incoherent motion (IVIM) of the thyroid, to determine base parameters in healthy volunteers, and to provide preliminary experience on clinical applicability in one patient. MATERIALS AND METHODS Eight healthy volunteers underwent 3T MRI using a diffusion weighted echo-planar imaging sequence with 12 different b-values between 0-800 s/mm2. The IVI...

متن کامل

Correlations between intravoxel incoherent motion (IVIM) parameters and histological findings in rectal cancer: preliminary results

Our purpose was to correlate different intravoxel incoherent motion (IVIM), histopathological and clinical parameters in rectal cancer. 17 patients with histologically proven rectal cancer investigated on a 3.T device were included into the study. DWI was performed using a multi-slice single-shot echo-planar imaging sequence with b values of 0, 50, 200, 500 and 1000 s/mm.2 A polygonal region of...

متن کامل

A Combined Use of Intravoxel Incoherent Motion MRI Parameters Can Differentiate Early-Stage Hepatitis-b Fibrotic Livers from Healthy Livers.

This study investigated a combined use of intravoxel incoherent motion (IVIM) parameters, Dslow ( D), PF ( f), and Dfast ( D*), for liver fibrosis evaluation. Sixteen healthy volunteers (F0) and 33 hepatitis-b patients (stage F1 = 15, stage F2-4 = 18) were included. With a 1.5 T MR scanner and respiration gating, IVIM diffusion-weighted imaging was acquired using a single-shot echo-planar imagi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiology

دوره 177 2  شماره 

صفحات  -

تاریخ انتشار 1990