OBJECTIVES The aims of this study were to test the utility of benchtop NGS platforms for NIPT for trisomy 21 using previously published z score calculation methods and to optimize the sample preparation and data analysis with use of in silico and physical size selection methods. METHODS Samples from 130 pregnant women were analyzed by whole genome sequencing on benchtop NGS systems Ion Torrent PGM and MiSeq. The targeted yield of 3 million raw reads on each platform was used for z score calculation. The impact of in silico and physical size selection on analytical performance of the test was studied. RESULTS Using a z score value of 3 as the cut-off, 98.11%-100% (104-106/106) specificity and 100% (24/24) sensitivity and 99.06%-100% (105-106/106) specificity and 100% (24/24) sensitivity were observed for Ion Torrent PGM and MiSeq, respectively. After in silico based size selection both platforms reached 100% specificity and sensitivity. Following the physical size selection z scores of tested trisomic samples increased significantly--p = 0.0141 and p = 0.025 for Ion Torrent PGM and MiSeq, respectively. CONCLUSIONS Noninvasive prenatal testing for chromosome 21 trisomy with the utilization of benchtop NGS systems led to results equivalent to previously published studies performed on high-to-ultrahigh throughput NGS systems. The in silico size selection led to higher specificity of the test. Physical size selection performed on isolated DNA led to significant increase in z scores. The observed results could represent a basis for increasing of cost effectiveness of the test and thus help with its penetration worldwide.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid prenatal testing using semiconductor sequencing?

Recent developments in sequencing technology have had a large impact in several areas of human genetics. One area in which the implementation of this new technology is closest to clinical use is prenatal testing. One tube of blood drawn from a pregnant woman is sufficient for testing the unborn child for Down syndrome with high diagnostic sensitivity and specificity. Approximately 10% of the DN...

متن کامل

Towards Clinical Molecular Diagnosis of Inherited Cardiac Conditions: A Comparison of Bench-Top Genome DNA Sequencers

BACKGROUND Molecular genetic testing is recommended for diagnosis of inherited cardiac disease, to guide prognosis and treatment, but access is often limited by cost and availability. Recently introduced high-throughput bench-top DNA sequencing platforms have the potential to overcome these limitations. METHODOLOGY/PRINCIPAL FINDINGS We evaluated two next-generation sequencing (NGS) platforms...

متن کامل

Development and Validation of a Next-Generation Sequencing Assay for BRCA1 and BRCA2 Variants for the Clinical Laboratory

The objective of this study was to design and validate a next-generation sequencing assay (NGS) to detect BRCA1 and BRCA2 mutations. We developed an assay using random shearing of genomic DNA followed by RNA bait tile hybridization and NGS sequencing on both the Illumina MiSeq and Ion Personal Gene Machine (PGM). We determined that the MiSeq Reporter software supplied with the instrument could ...

متن کامل

Performance comparison of Illumina and ion torrent next-generation sequencing platforms for 16S rRNA-based bacterial community profiling.

High-throughput sequencing of the taxonomically informative 16S rRNA gene provides a powerful approach for exploring microbial diversity. Here we compare the performances of two common "benchtop" sequencing platforms, Illumina MiSeq and Ion Torrent Personal Genome Machine (PGM), for bacterial community profiling by 16S rRNA (V1-V2) amplicon sequencing. We benchmarked performance by using a 20-o...

متن کامل

Feasibility study of semiconductor sequencing for noninvasive prenatal detection of fetal aneuploidy.

BACKGROUND Noninvasive prenatal detection of common fetal aneuploidies with cell-free DNA from maternal plasma has been achieved with high-throughput next-generation sequencing platforms. Turnaround times for previously tested platforms are still unsatisfactory for clinical applications, however, because of the time spent on sequencing. The development of semiconductor sequencing technology has...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • PloS one

دوره 10 12  شماره 

صفحات  -

تاریخ انتشار 2015